Electrical Wiring of the Aldehyde Oxidoreductase PaoABC with a Polymer Containing Osmium Redox Centers: Biosensors for Benzaldehyde and GABA

نویسندگان

  • Artavazd Badalyan
  • Marlen Dierich
  • Konstanze Stiba
  • Viola Schwuchow
  • Silke Leimkühler
  • Ulla Wollenberger
چکیده

Biosensors for the detection of benzaldehyde and γ-aminobutyric acid (GABA) are reported using aldehyde oxidoreductase PaoABC from Escherichia coli immobilized in a polymer containing bound low potential osmium redox complexes. The electrically connected enzyme already electrooxidizes benzaldehyde at potentials below -0.15 V (vs. Ag|AgCl, 1 M KCl). The pH-dependence of benzaldehyde oxidation can be strongly influenced by the ionic strength. The effect is similar with the soluble osmium redox complex and therefore indicates a clear electrostatic effect on the bioelectrocatalytic efficiency of PaoABC in the osmium containing redox polymer. At lower ionic strength, the pH-optimum is high and can be switched to low pH-values at high ionic strength. This offers biosensing at high and low pH-values. A "reagentless" biosensor has been formed with enzyme wired onto a screen-printed electrode in a flow cell device. The response time to addition of benzaldehyde is 30 s, and the measuring range is between 10-150 µM and the detection limit of 5 µM (signal to noise ratio 3:1) of benzaldehyde. The relative standard deviation in a series (n = 13) for 200 µM benzaldehyde is 1.9%. For the biosensor, a response to succinic semialdehyde was also identified. Based on this response and the ability to work at high pH a biosensor for GABA is proposed by coimmobilizing GABA-aminotransferase (GABA-T) and PaoABC in the osmium containing redox polymer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Osmium Bipyridyl Redox Polymers Used in Enzyme Electrodes

A review of the background of biosensors which utilise osmium complexes for monitoring the glucose levels in diabetic patients is presented. A n electrochemical system, based on an osmium redox polymer, is described; the system is aimed at being a reliable, compact and miniature in vivo sensor for implantation into diabetic patients for continuous monitoring of their blood glucose levels. The s...

متن کامل

Rapid Determination of Sucrose in Fruit Juices: A New Sensitive Carbon Nanotube Paste Osmium-Polymer Mediated Biosensor

The aim of the present work was the development of a novel amperometric biosensor for rapid detection of sucrose in fruit juices samples. Two enzymes, invertase and fructose dehydrogenase (FDH), were immobilized onto a single-walled carbon nanotube paste (SWCNTP) electrode by wiring with a highly original osmium-polymer hydrogel. A second biosensor, for fructose only, was constructed containing...

متن کامل

Characterization of different FAD-dependent glucose dehydrogenases for possible use in glucose-based biosensors and biofuel cells

In this study, different flavin adenine dinucleotide (FAD)-dependent glucose dehydrogenases (FADGDHs) were characterized electrochemically after "wiring" them with an osmium redox polymer [Os(4,4'-dimethyl-2,2'-bipyridine)(2)(PVI)(10)Cl](+) on graphite electrodes. One tested FADGDH was that recently discovered in Glomerella cingulata (GcGDH), another was the recombinant form expressed in Pichia...

متن کامل

Electroanalytical properties of aldehyde biosensors with a hybrid-membrane composed of an enzyme film and a redox Os-polymer film.

Aldehyde biosensors were constructed by cross-linking formaldehyde dehydrogenase (FDH) or aldehyde dehydrogenase (ADH) and bovine serum albumin on the surface of a redox Os-polymer-coated electrode. The prepared aldehyde biosensors responded rapidly (within 30 s) to aldehydes without the addition of a soluble mediator, because the inner redox Os-polymer film effectively mediated the electron tr...

متن کامل

Small electron-transfer proteins as mediators in enzymatic electrochemical biosensors.

Electrochemical mediators transfer redox equivalents between the active sites of enzymes and electrodes and, in this way, initiate bioelectrocatalytic redox processes. This has been very useful in the development of the so-called second-generation biosensors, in which they transduce a catalyzed reaction into an electrical signal. Among other pre-requisites, redox mediators must be readily oxidi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2014