A comparison of neodymium: yttrium aluminum garnet and diode laser transscleral cyclophotocoagulation and cyclocryotherapy.

نویسندگان

  • E I Assia
  • H L Hennis
  • W C Stewart
  • U F Legler
  • A N Carlson
  • D J Apple
چکیده

The cyclodestructive effects of cyclocryotherapy and of the neodymium:yttrium aluminum garnet (Nd:YAG) and diode laser transscleral cyclophotocoagulation were investigated in phakic and pseudophakic cadaver eyes using a modified Miyake posterior-view technique and light microscopy. Cyclocryotherapy to -80 degrees C was applied with a 2.5-mm diameter tip, 1 and 2 mm from the limbus. Freezing at the ciliary processes was evident after 10-15 sec and reached a diameter of 3-4 mm by 30 sec. No visible changes were evident grossly in the ciliary processes, crystalline lens, or intraocular lens. Histologically increased separation of cells was observed. Effective noncontact Nd:YAG and diode laser applications to the ciliary processes were observed grossly as tissue blanching and shrinking and pigment dispersion. This effect was obtained by aiming 0.5-1.0 mm behind the limbus at a 1-mm defocus using 4 J of energy for the Nd:YAG and 1.2 J for the diode laser. The diode laser spot size did not affect the tissue response. No damage was observed in the crystalline or intraocular lens with either type of laser. Histologic changes using both lasers were coagulation necrosis with fragmentation and detachment of the ciliary body epithelium. This study suggested that the gross and histologic thermal effects produced by the diode and Nd:YAG laser were similar in the ciliary body. Also, at the time of surgery, these cyclodestructive procedures potentially cause little alteration of the crystalline or intraocular lens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Glaucoma Escalation after Penetrating Keratoplasty

Purpose: Glaucoma following penetrating keratoplasty (PK) continues to be a serious problem that may ultimately become sight threatening. Knowledge of the risk factors for development of glaucoma following PK, such as preexisting glaucoma, pseudophakia, aphakia, and previous PK, can limit the occurrence and improve the outcome of the keratoplasty. The management of postkeratoplasty (Post-PK) gl...

متن کامل

Changes in aqueous outflow after in vitro neodymium: yttrium aluminum garnet laser cyclophotocoagulation.

To examine the possible role of transscleral outflow routes, enucleated human and porcine eyes underwent noncontact neodymium:yttrium aluminum garnet (Nd:YAG) laser cyclophotocoagulation 3 mm posterior to the limbus. Pars plana lesions were verified histologically. The eyes were perfused with saline solution at 50 mm Hg perfusion pressure, placing the tip of the needle into the hyaloid orbicula...

متن کامل

Clinical comparison of semiconductor diode versus neodymium: YAG non-contact cyclo photocoagulation.

AIMS The advent of diode lasers has allowed their use in transscleral cyclo photocoagulation for refractory glaucoma. A trial was performed to compare the ocular hypotensive and inflammatory effects of cyclo photocoagulation using a continuous wave diode (810 nm) and a free running neodymium:yttrium aluminium garnet (Nd:YAG) laser (1064 nm). METHODS Forty patients with refractory glaucoma wer...

متن کامل

In vitro Evaluation of Dentin Surface Irradiated by Neodymium-doped: Yttrium Aluminum Garnet Laser (Nd: YAG) Using Scanning Electron Microscopy

Introdouction: Dentinal hypersensitivity (DH) is one of the most painful chronic problems reported in dental offices. Various methods have been applied for the treatment of DH. However, majority of them are either ineffective or last for a short period of time. It has been reported that lasers, particularly Neodymium- doped: Yttrium Aluminum Garnet laser (Nd: YAG), can be helpful in the treatme...

متن کامل

Cryogenically cooled 946nm Nd:YAG laser.

We present the first multi-Watt demonstration of a diode pumped cryogenically cooled neodymium-doped yttrium aluminum garnet (YAG) laser operating at 946 nm on the (4)F(3/2) → (4)I(9/2) transition. 3.8 W of continuous wave output power for 12.8 W of absorbed pump was obtained with a slope efficiency of 47%. In addition, we made an extensive characterization of the spectroscopic properties aroun...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 32 10  شماره 

صفحات  -

تاریخ انتشار 1991