UNLABELLED Couplings between uterine contractions (UC) and fetal heart rate (fHR) provide important information on fetal condition during labor. At present, couplings between UC and fHR are assessed by visual analysis and interpretation of cardiotocography. The application of computerized approaches is restricted due to the non-stationarity of the signal, missing data and noise, typical for fHR. Herein, we propose a novel approach to assess couplings between UC and fHR, based on a signal-processing algorithm termed bivariate phase-rectified signal averaging (BPRSA). METHODS Electrohysterogram (EHG) and fetal electrocardiogram (fECG) were recorded non-invasively by a trans-abdominal device in 73 women at term with uneventful singleton pregnancy during the first stage of labor. Coupling between UC and fHR was analyzed by BPRSA and by conventional cross power spectral density analysis (CPSD). For both methods, degree of coupling was assessed by the maximum coefficient of coherence (CPRSA and CRAW, respectively) in the UC frequency domain. Coherence values greater than 0.50 were consider significant. CPRSA and CRAW were compared by Wilcoxon test. RESULTS At visual inspection BPRSA analysis identified coupled periodicities in 86.3% (63/73) of the cases. 11/73 (15%) cases were excluded from further analysis because no 30 minutes of fECG recording without signal loss was available for spectral analysis. Significant coupling was found in 90.3% (56/62) of the cases analyzed by BPRSA, and in 24.2% (15/62) of the cases analyzed by CPSD, respectively. The difference between median value of CPRSA and CRAW was highly significant (0.79 [IQR 0.69-0.90] and 0.29 [IQR 0.17-0.47], respectively; p<0.0001). CONCLUSION BPRSA is a novel computer-based approach that can be reliably applied to trans-abdominally acquired EHG-fECG. It allows the assessment of correlations between UC and fHR patterns in the majority of labors, overcoming the limitations of non-stationarity and artifacts. Compared to standard techniques of cross-correlations, such as CPSD, BPRSA is significantly superior.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bivariate phase - rectified signal averaging

Phase-Rectified Signal Averaging (PRSA) was shown to be a powerful tool for the study of quasi-periodic oscillations and nonlinear effects in non-stationary signals. Here we present a bivariate PRSA technique for the study of the inter-relationship between two simultaneous data recordings. Its performance is compared with traditional cross-correlation analysis, which, however, does not work wel...

متن کامل

A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment

Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant.Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a be...

متن کامل

Uterine Electromyography in Humans – Contractions, Labor, and Delivery

Today’s maternal/fetal monitoring lacks the capability to diagnose labor and predict delivery. The objective of this work was to demonstrate that uterine electromyography (EMG) is proven to be a viable alternative to current monitoring techniques. Uterine EMG was monitored noninvasively and trans-abdominally from pregnant patients using surface electrodes. Several aspects of the uterine EMG wer...

متن کامل

Phase-rectified signal averaging as a sensitive index of autonomic changes with aging.

Standard heart rate variability (HRV) techniques have been questioned in the sleep and autonomic fields as imprecise measures of sympathetic and parasympathetic activity. A new technique has emerged, known as phase-rectified signal averaging (PRSA). PRSA is used to quantify the quasi-periodic accelerations and decelerations in short-term heart rate, an effect that is normally masked by artifact...

متن کامل

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014