Impact of esophageal temperature monitoring guided atrial fibrillation ablation on preventing asymptomatic excessive transmural injury

نویسندگان

  • Kunihiko Kiuchi
  • Katsunori Okajima
  • Akira Shimane
  • Gaku Kanda
  • Kiminobu Yokoi
  • Jin Teranishi
  • Kousuke Aoki
  • Misato Chimura
  • Takayoshi Toba
  • Shogo Oishi
  • Takahiro Sawada
  • Yasue Tsukishiro
  • Tetsuari Onishi
  • Seiichi Kobayashi
  • Yasuyo Taniguchi
  • Shinichiro Yamada
  • Yoshinori Yasaka
  • Hiroya Kawai
  • Akihiro Yoshida
  • Koji Fukuzawa
  • Mitsuaki Itoh
  • Kimitake Imamura
  • Ryudo Fujiwara
  • Atsushi Suzuki
  • Tomoyuki Nakanishi
  • Soichiro Yamashita
  • Ken-ichi Hirata
  • Hiroshi Tada
  • Hiro Yamasaki
  • Yoshihisa Naruse
  • Miyako Igarashi
  • Kazutaka Aonuma
چکیده

BACKGROUND Even with the use of a reduced energy setting (20-25 W), excessive transmural injury (ETI) following catheter ablation of atrial fibrillation (AF) is reported to develop in 10% of patients. However, the incidence of ETI depends on the pulmonary vein isolation (PVI) method and its esophageal temperature monitor setting. Data comparing the incidence of ETI following AF ablation with and without esophageal temperature monitoring (ETM) are still lacking. METHODS This study was comprised of 160 patients with AF (54% paroxysmal, mean: 24.0±2.9 kg/m(2)). Eighty patients underwent ablation accompanied by ETM. The primary endpoint was defined as the occurrence of ETI assessed by endoscopy within 5 d after the AF ablation. The secondary endpoint was defined as AF recurrence after a single procedure. If the esophageal temperature probe registered >39 °C, the radiofrequency (RF) application was stopped immediately. RF applications could be performed in a point-by-point manner for a maximum of 20 s and 20 W. ETI was defined as any injury that resulted from AF ablation, including esophageal injury or periesophageal nerve injury (peri-ENI). RESULTS The incidence of esophageal injury was significantly lower in patients whose AF ablation included ETM compared with patients without ETM (0 [0%] vs. 6 [7.5%], p=0.028), but not the incidence of peri-ENI (2 [2.5%] vs. 3 [3.8%], p=1.0). AF recurrence 12 months after the procedure was similar between the groups (20 [25%] in the ETM group vs. 19 [24%] in the non-ETM group, p=1.00). CONCLUSIONS Catheter ablation using ETM may reduce the incidence of esophageal injury without increasing the incidence of AF recurrence but not the incidence of peri-ENI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Esophageal Temperature Monitoring During Radiofrequency Ablation of Atrial Fibrillation: A Meta-Analysis.

Objective: Atrio-esophageal fistula is an infrequent but devastating complication of catheter-based ablation of atrial fibrillation (AF). Thermal esophageal injury may be the precursor of atrio-esophageal fistula. Here, we evaluated the role of esophageal temperature monitoring in preventing thermal esophageal injury during pulmonary vein isolation for AF with radiofrequency energy. Methods: In...

متن کامل

Luminal esophageal temperature monitoring with a deflectable esophageal temperature probe and intracardiac echocardiography may reduce esophageal injury during atrial fibrillation ablation procedures: results of a pilot study.

BACKGROUND Luminal esophageal temperature (LET) monitoring is one strategy to minimize esophageal injury during atrial fibrillation ablation procedures. However, esophageal ulceration and fistulas have been reported despite adequate LET monitoring. The objective of this study was to assess a novel approach to LET monitoring with a deflectable LET probe on the rate of esophageal injury in patien...

متن کامل

Esophageal injury and temperature monitoring during atrial fibrillation ablation.

BACKGROUND It is common practice to empirically limit the radiofrequency (RF) power when ablating the posterior left atrium during atrial fibrillation ablation to avoid thermal injury to the esophagus. The objective of this study was to determine whether RF energy delivery limited by luminal esophageal temperature (LET) monitoring is associated with a reduction in esophageal injury compared wit...

متن کامل

Electrical and thermal effects of esophageal temperature probes on radiofrequency catheter ablation of atrial fibrillation: results from a computational modeling study.

INTRODUCTION Luminal esophageal temperature (LET) monitoring is commonly employed during catheter ablation of atrial fibrillation (AF) to detect high esophageal temperatures during radiofrequency (RF) delivery along the posterior wall of the left atrium. However, it has been recently suggested that in some cases the esophageal probe itself may serve as an RF "antenna" and promote esophageal the...

متن کامل

Entire posterior wall isolation in an unusual case of common ostium between the right inferior and left inferior pulmonary veins.

Atrio-esophageal fistula as a complication of percutaneous transcatheter ablation of atrial fibrillation. ablation with esophageal cooling with a cooled water-irrigated intraesophageal balloon: a pilot study. A et al. Clinical characteristics of massive air embolism complicating left atrial ablation of atrial fibrillation: lessons from five cases. A et al. Prevention of periprocedural ischemic ...