A system for toxicological screening by capillary gas chromatography with use of a drug retention index based on nitrogen-containing reference compounds.
نویسندگان
چکیده
Capillary gas chromatography with nitrogen-specific detection allows rapid screening of numerous drugs of toxicological interest. However, for accurate identification of individual peaks, the system must be well calibrated, e.g., through the use of retention indices (RI). To overcome problems associated with the use of RI's based on homologous series determined with nitrogen-specific detectors, we have developed an RI reference system based on molecular masses and retention times of nitrogen-containing compounds. The standards chosen are easily available in highly purified form and can be detected by the unmodified nitrogen-specific detector. By using temperature programming, we can obtain a linear relationship between the molecular masses of standards and their retention times. Used in conjunction with microcomputer data handling, this screening system is rugged and reliable, operating 22 h per day. In the past two years, we have screened greater than 3000 samples (blood, serum, urine, gastric lavage) without major problems.
منابع مشابه
Applications of an HPLC-DAD drug-screening system based on retention indices and UV spectra.
An analytical database, using high-performance liquid chromatography (HPLC) with diode array ultraviolet (UV) detection, of over 250 toxicologically relevant drugs has been extensively applied to both clinical and forensic toxicology. This general drug screening system, based on a mixed-phase (octadecyl/cyanopropyl) column and gradient reversed-phase HPLC, can identify a wide range of basic, ac...
متن کاملScreening and quantification of hypnotic sedatives in serum by capillary gas chromatography with a nitrogen-phosphorus detector, and confirmation by capillary gas chromatography-mass spectrometry.
We describe a quantitative screen for hypnotic-sedative drugs in which we use capillary gas chromatography with a nitrogen-phosphorus detector (GC/NPD) as the primary method and capillary gas chromatography-mass spectrometry (GC-MS) for confirmation. GC retention times of the acid-extracted underivatized drugs were stable (CVs less than 1%), and the detector response varied linearly over a 20-f...
متن کاملScreening for neutral and basic drugs in blood by dual fused-silica column chromatography with nitrogen-phosphorus detection.
We describe a capillary gas-chromatographic method for detection and quantification of basic and neutral drugs in the plasma of patients thought to be poisoned after dangerous overdose. Without further derivatization, the drugs are extracted from 1 mL of plasma, at basic pH, into diethyl ether. The extracts are injected onto two fused-silica capillary columns of different polarity (Ultra 1 and ...
متن کاملFragment screening of cyclin G-associated kinase by weak affinity chromatography
Fragment-based drug discovery (FBDD) has become a new strategy for drug discovery where lead compounds are evolved from small molecules. These fragments form low affinity interactions (dissociation constant (K(D)) = mM - μM) with protein targets, which require fragment screening methods of sufficient sensitivity. Weak affinity chromatography (WAC) is a promising new technology for fragment scre...
متن کاملEffect of Composition on Release of Aroma Compounds
The effect of oleic acid (5 and 10% v/v) and xanthan gum (0.5 and 1% wt) on partitioning and retention of ethyl acetate and diacetyl from two matrices with a different composition was investigated by applying static head space gas chromatography. Two matrices with different composition have been developed: one containing carbohydrates (xanthan gum) and in the second one, called co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 35 4 شماره
صفحات -
تاریخ انتشار 1989