Chlorhexidine gluconate–impregnated central access catheter dressings as a cause of erosive contact dermatitis: a report of 7 cases.
نویسندگان
چکیده
BACKGROUND Chlorhexidine gluconate-impregnated dressings have become widely adopted as a means to reduce the risk for catheter-associated bloodstream infections. These dressings release antiseptic under occlusion onto the skin surrounding catheter insertion sites. Although chlorhexidine gluconate is a known cause of contact dermatitis, the phenotypic range of this adverse effect of chlorhexidine gluconate–impregnated dressings in critically ill patients has not been described. OBSERVATIONS We report 7 cases of erosive irritant contact dermatitis due to chlorhexidine gluconate-impregnated transparent dressings. Six of these patients were children (age range, 4 months to 2 years); the adult was a critically ill 62-year-old man. Four patients were immunosuppressed after solid organ transplant and all were receiving blood pressure support at the time of this reaction. The insertion sites of femoral catheters were involved in all but 1 case; 3 catheter sites were involved in the adult patient. Results of extensive infectious workups were negative. All lesions resolved with discontinuation of the chlorhexidine gluconate-containing dressings, local wound care, and alternative antimicrobial dressings. CONCLUSIONS Erosive contact dermatitis is an under-recognized complication of chlorhexidine gluconate-impregnated dressings. Health care providers should be aware of this risk, particularly in young children and immunosuppressed and/or critically ill patients, who may be more susceptible to the irritant effects of these dressings. When the dressings are used, patients should be monitored closely for skin breakdown.
منابع مشابه
Chlorhexidine-impregnated sponges and less frequent dressing changes for prevention of catheter-related infections in critically ill adults: a randomized controlled trial.
CONTEXT Use of a chlorhexidine gluconate-impregnated sponge (CHGIS) in intravascular catheter dressings may reduce catheter-related infections (CRIs). Changing catheter dressings every 3 days may be more frequent than necessary. OBJECTIVE To assess superiority of CHGIS dressings regarding the rate of major CRIs (clinical sepsis with or without bloodstream infection) and noninferiority (less t...
متن کاملAntimicrobial Activity of a Novel Vascular Access Film Dressing Containing Chlorhexidine Gluconate
BACKGROUND Covering insertion sites with chlorhexidine impregnated dressings has been proven to be clinically effective in reducing catheter related blood stream infections (CR-BSI). Two chlorhexidine gluconate (CHG)-impregnated dressings are commercially available, a polyurethane foam disk and a film dressing containing a chlorhexidine gluconate-impregnated gel pad. While both have demonstrate...
متن کاملTegaderm CHG IV Securement Dressing for Central Venous and Arterial Catheter Insertion Sites: A NICE Medical Technology Guidance
Catheters are widely used for vascular access and for the administration of drugs or fluids in critically ill patients. This exposes patients to an infection risk. Tegaderm chlorhexidine gluconate (CHG) (developed by 3M)-a transparent securement dressing-covers and protects catheter sites and secures devices to the skin. It comprises a transparent adhesive dressing to act as a barrier against e...
متن کاملAllergic dermatitis caused by povidone iodine: an uncommon complication of chronic peritoneal dialysis treatment.
Allergic dermatitis around the catheter exit site, caused by topical antiseptics such as povidone iodine and chlorhexidine gluconate, is an uncommon complication in patients on chronic peritoneal dialysis (CPD). As yet, published reports concerning this rare non catheter-related complication are few. The frequency of this type of dermatitis is not known, because reports of isolated cases consti...
متن کاملSuppression of regrowth of normal skin flora under chlorhexidine gluconate dressings applied to chlorhexidine gluconate-prepped skin.
BACKGROUND Catheter colonization and bloodstream infection during the first week after insertion of a central venous catheter have been shown to result from the patient's own skin flora. METHODS The backs of 32 healthy subjects were prepped with a 2% chlorhexidine gluconate (CHG)/70% isopropyl alcohol antiseptic. Three dressings, 2 of which contained CHG, were placed on the prepped skin in a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JAMA dermatology
دوره 149 2 شماره
صفحات -
تاریخ انتشار 2013