Spin - down rate and inferred dipole magnetic field of the soft gamma - ray repeater SGR 1627 – 41

نویسندگان

  • R. Turolla
  • S. Zane
  • A. De Luca
  • A. Tiengo
  • G. L. Israel
  • F. Mattana
  • S. Mereghetti
  • M. Bailes
  • P. Romano
  • D. Götz
چکیده

Using Chandra data taken on 2008 June, we detected pulsations at 2.594 39(4) s in the soft gamma-ray repeater SGR 1627–41. This is the second measurement of the source spin period and allows us to derive for the first time a long-term spin-down rate of (1.9 ± 0.4) × 10 s s. From this value we infer for SGR 1627–41 a characteristic age of ∼2.2 kyr, a spin-down luminosity of ∼4 × 10 erg s (one of the highest among sources of the same class), and a surface dipole magnetic field strength of ∼2×10 G. These properties confirm the magnetar nature of SGR 1627–41; however, they should be considered with caution since they were derived on the basis of a period derivative measurement made using two epochs only and magnetar spin-down rates are generally highly variable. The pulse profile, double-peaked and with a pulsed fraction of (13 ± 2)% in the 2–10 keV range, closely resembles that observed by XMM-Newton in 2008 September. Having for the first time a timing model for this SGR, we also searched for a pulsed signal in archival radio data collected with the Parkes radio telescope nine months after the previous X-ray outburst. No evidence for radio pulsations was found, down to a luminosity level ∼10–20 times fainter (for a 10% duty cycle and a distance of 11 kpc) than the peak luminosity shown by the known radio magnetars.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Discovery of a New Soft Gamma Repeater , Sgr 1627 – 41

We report the discovery of a new soft gamma repeater (SGR), SGR 1627–41, and present BATSE observations of the burst emission and BeppoSAX NFI observations of the probable persistent Xray counterpart to this SGR. All but one burst spectrum are well fit by an optically thin thermal bremsstrahlung (OTTB) model with kT values between 25 and 35 keV. The spectrum of the X-ray counterpart, SAX J1635....

متن کامل

SGR 0418+5729—HOW DOES A YOUNG NEUTRON STAR SPIN DOWN TO A 9 s PERIOD WITH A DIPOLE FIELD LESS THAN 1013 G?

The period derivative bound for the soft gamma-ray repeater SGR 0418+5729 establishes the magnetic dipole moment to be distinctly lower than the magnetar range, placing the source beyond the regime of isolated pulsar activity in the P–Ṗ diagram and giving a characteristic age >2 × 107 yr, much older than the 105 yr age range of SGRs and anomalous X-ray pulsars. So the spin-down must be produced...

متن کامل

XMM-Newton observations of the Soft Gamma Ray Repeater SGR 1627–41 in a low luminosity state

The sky region containing the soft gamma-ray repeater SGR 1627–41 has been observed three times with XMM-Newton in February and September 2004. SGR 1627–41 has been detected with an absorbed flux of ∼9×10 erg cm s (2-10 keV). For a distance of 11 kpc, this corresponds to a luminosity of ∼3×10 erg s, the smallest ever observed for a Soft Gamma Repeater and possibly related to the long period of ...

متن کامل

XMM-Newton observation of the Soft Gamma Ray Repeater SGR 1627–41 in a low luminosity state

The sky region containing the soft gamma-ray repeater SGR 1627–41 and the hard X-ray transient IGR J16358–4726 has been observed with XMM-Newton in September 2004. SGR 1627–41 has been detected with an absorbed flux of ∼9×10 erg cm s (2-10 keV), slightly smaller than that seen with Chandra in 2001-2003. For a distance of 11 kpc, this corresponds to a luminosity of ∼3×10 erg s, the smallest ever...

متن کامل

Precise Localization of the Soft Gamma Repeater SGR 1627−41 and the Anomalous X-ray Pulsar AXP 1E1841−045 with Chandra

We present precise localizations of AXP 1E1841−045 and SGR 1627−41 with Chandra. We obtained new infrared observations of SGR 1627−41 and reanalyzed archival observations of AXP 1E1841−045 in order to refine their positions and search for infrared counterparts. A faint source is detected inside the error circle of AXP 1E1841−045. In the case of SGR 1627−41, several sources are located within th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009