Intra-MRI extraction of diagnostic electrocardiograms using dynamic feedback from carotidal magnetohydrodynamic voltages

نویسندگان

  • Thomas S Gregory
  • Kevin J Wu
  • Ehud J Schmidt
  • John Oshinski
  • Zion T Tse
چکیده

Background During Cardiac Magnetic Resonance Imaging (CMR), blood plasma electrolytes ejected into the aorta during early systole interact with the static magnetic field of the MR scanner (B0) to produce a Magnetohydrodynamic (MHD) Effect [1]. Electrocardiograms (ECGs) recorded in the presence of B0 are overlaid with induced MHD voltages (VMHD), leading to non-robustly synchronized imaging [2], and preventing reliable physiological monitoring inside the MRI [3]. Previous methods have sought to separate between VMHD and the true ECG (ECGreal) through adaptive filtering [3], independent component analysis [4], and advanced computational models [5]. However, these methods are based on a static model, which has limited accuracy during varying-rate heart-beats. We aim to develop accurate ECGreal extraction, as well as real-time Stroke Volume (SV) estimation (proportional to the integral of MHD over systole) [6], with the advantage of physiological feedback through the real-time monitoring of common carotidal MHD, through which the previously static MHD template can be dynamically updated, providing an increased level of accuracy during variations in heart rate, and a continuous estimation of VMHD and ECGreal, for the patient’s entire duration inside the MRI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid quantification of stroke volume using magnetohydrodynamic voltages in 3T MRI: a feasibility study

Background The Electrocardiogram (ECG) is a standard clinical tool for cardiac physiological monitoring, required for cardiac synchronization during cardiac MRI, despite signal artifacts resulting from Magnetohydrodynamic voltages (VMHD). VMHD becomes significant during systole when rapidly ejected blood from the left ventricle into the aortic arch interacts with the strong magnetic field (B0) ...

متن کامل

Continuous Rapid Quantification of Stroke Volume Using Magnetohydrodynamic Voltages in 3T Magnetic Resonance Imaging.

BACKGROUND To develop a technique to noninvasively estimate stroke volume in real time during magnetic resonance imaging (MRI)-guided procedures, based on induced magnetohydrodynamic voltages (VMHD) that occur in ECG recordings during MRI exams, leaving the MRI scanner free to perform other imaging tasks. Because of the relationship between blood flow (BF) and VMHD, we hypothesized that a metho...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

Improving the performance of neural network in differentiation of breast tumors using wavelet transformation on dynamic MRI

 ABSTRACT Background: A computer aided diagnosis system was established using the wavelet transform and neural network to differentiate malignant from benign in a   group of patients with histo-pathologically proved breast lesions based on the data derived independ­ently from time-intensity profile.   Materials and Methods: The per­formance of the artificial neural network (ANN) was evaluated u...

متن کامل

ECG Electrode Placements for Magnetohydrodynamic Voltage Suppression and improving Cardiac Gating in high-field MRI

Background The accuracy of Electrocardiogram (ECG) gating for synchronization of MR scanner image acquisition and cardiac electrical activity is of great importance for acquiring high-quality Cardiac Magnetic Resonance (CMR) images free of motion artefacts. The distortion of ECG traces by Magnetohydrodynamic Voltages (VMHD) induced by interaction between the MRI static magnetic field (B0) and r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016