Measurement of thoracoabdominal asynchrony: importance of sensor sensitivity to cross section deformations.

نویسندگان

  • A de Groote
  • Y Verbandt
  • M Paiva
  • P Mathys
چکیده

Discrepancies in the assessment of thoracoabdominal asynchrony are observed depending on the choice of respiratory movement sensors. We test the hypothesis that these discrepancies are due to a different dependence of the sensors on cross-sectional perimeter and area variations of the chest wall. First, we study the phase shift between perimeter and area (Phi(PA)) for an elliptical model, which is deformed by sinusoidal changes of its principal axes. We show that perimeter and area vary sinusoidally in the physiological range of deformations, and we discuss how Phi(PA) depends on the ellipticity of the cross section, on the ratio of transverse and dorsoventral movement amplitudes, and on their phase difference. Second, we compute the relationship between perimeter, area, and the output of the inductive sensor, and we proceed by comparing inductive plethysmography with strain gauges for several cross section deformations. We demonstrate that both sensors can provide different phase information for identical cross section deformations and, hence, can estimate thoracoabdominal asynchrony differently. Furthermore, the complex dependence of the inductive sensor on perimeter and area warns against this sensor for the evaluation of thoracoabdominal asynchrony.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Enhancement of Fiber Optic Diesel Adulteration Detection Sensor Using Stripped Clad SBend Section

A novel geometry for enhancing the sensitivity of intensity modulated refractometric fiber optic sensor for detection of adulteration level in diesel by kerosene is proposed. In this multimode plastic optical fiber is uncladded for specific length and bent into S shape. This geometry is simulated and analyzed using Beam Propagation Method in Beam prop RSOFT software. When sensor is immersed in ...

متن کامل

Asynchrony and hyperinflation in patients with chronic obstructive pulmonary disease during two types of upper limbs exercise.

INTRODUCTION Occurrence of dynamic hyperinflation during upper-limbs exercises in chronic obstructive pulmonary disease (COPD) patients it is not well established. We hypothesized that dynamic hyperinflation and thoracoabdominal asynchrony occurs in COPD patients accomplishing arms exercises. We assessed the occurrence and association of dynamic hyperinflation and thoracoabdominal asynchrony in...

متن کامل

Pressure sensor plethysmography: a method for assessment of respiratory motion in children.

Noncalibrated respiratory inductance plethysmography has been used to measure respiratory function by calculation of the phase angle and, more recently, by determination of the ratio of each time to reach peak tidal expiratory flow to total expiratory time (TPEF/TE). Since TPEF/TE is known to be decreased in airway obstruction when derived from flow signals obtained by a pneumotachograph, we wa...

متن کامل

Four-wire orthogonal structure for accurate measurement of fluid velocity and wind flow direction using silicon micro-machining on silicon nitride membranes

Microelectromechanical thermal sensors are one of the most accurate and important tools for measuring the direction and velocity of an acoustic wave and winds. Detection of wind direction and speed in different ranges has different applications such as meteorology, wind power plants, gas flow measurement in smart building and gas consumption of power plants. In this paper, a four wires sensor i...

متن کامل

FEM Updating of Ship Structure by The Sensitivity Equation of Transmissibility Function

This study presents a novel sensitivity-based finite element model updating approach to estimate structural parameters using output-only data. A quasi-exact sensitivity relation based on transmissibility data is introduced. Partially measured structural responses are included in mathematical formulations to address incomplete measurement problems and improve the accuracy of the sensitivity rela...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 88 4  شماره 

صفحات  -

تاریخ انتشار 2000