Integrated Electronic Load Controller with T-Connected Transformer for Isolated Asynchronous Generator

نویسندگان

  • Bhim Singh
  • V. Rajagopal
چکیده

This paper deals with a integrated Electronic Load Controller (IELC) for an isolated asynchronous generator (IAG), used in constant power pico hydro power generation for feeding three-phase four-wire loads. The proposed IELC is used to control the voltage and frequency of IAG in the integrated manner. This IELC is realised using a T-connected transformer and three-leg insulated gate bipolar transistors (IGBTs) based current controlled voltage source converter (VSC) a capacitor, a chopper switch and an auxiliary load on its dc bus. The proposed IELC with an isolated generating system is modeled and simulated in MATLAB along with Simulink and power system blockset (PSB) toolboxes. The simulated results of IAG-IELC system are presented to demonstrate its performance for feeding three-phase four-wire linear/nonlinear (balanced/unbalanced) loads with the neutral current compensation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wind Energy Conversion System Connected With Grid Using Permanent Magnet Synchronous Generator (PMSG)

This paper deals with permanent magnet synchronous generator (PMSG) based wind energy conversion system (WECS) integrated with grid with two back to back connected converters with a common DC link. The aim of this research is to model control of direct driven 1.5 MW wind turbine permanent magnetic synchronous generator (PMSG) which feeds alternating current (AC) power to the utility grid .The m...

متن کامل

Flexible Power Electronic Transformer for Power Flow Control Applications

This paper proposes a Flexible Power Electronic Transformer (FPET) for the application in the micro-grids. The low frequency transformer is usually used at the Point of Common Coupling (PCC) to connect the low voltage grid and utility network to each other. The conventional 50Hz transformer results in enhanced low voltage-grid power management system during grid-connected operation. In this pap...

متن کامل

Comparative Power Quality Analysis of Different DSTATCOM Topologies

This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total har...

متن کامل

Battery Energy Storage System Based Controller for a Wind Turbine Driven Isolated Asynchronous Generator

This paper presents an investigation of a voltage and frequency controller for an isolated asynchronous generator (IAG) driven by a wind turbine and supplying 3-phase 4-wire loads to the isolated areas where a grid is not accessible. The control strategy is based on the indirect current control of the VSC (voltage source converter) using the frequency PI controller. The proposed controller cons...

متن کامل

Isolated Pico-Hydropower Generation for Power Quality Improvement Using 24 Pulse Ac-Dc Converter

A comparative study between the topologies consisting of the Conventional Electronic Load Controller and the Proposed Electronic Load controller (ELC)has been carried out in this paper for the power Quality Improvement in a conventional Electronic Load controller used for Isolated pico-hydropower generation using Asynchronous generator (AG). A polygon wound autotransformer with reduced Kilo Vol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011