Variability between laboratories performing coagulation tests with identical platforms: a nationwide evaluation study
نویسندگان
چکیده
BACKGROUND While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.
منابع مشابه
Prothrombin time testing practices: adherence to guidelines and standards.
Coagulation laboratory tests are vital to the diagnosis, treatment, and management of bleeding and hypercoagulability disorders. Some laboratories, however, fail to follow voluntary practice guidelines for coagulation testing (1, 2), and inappropriate performance of coagulation tests, such as the prothrombin time (PT) test, may contribute to coagulation and bleeding complications (3, 4). A 2001...
متن کاملI-4: External Quality Assessment - A Necessity in The Andrology Laboratory
Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...
متن کاملLaboratory assessment of novel oral anticoagulants: method suitability and variability between coagulation laboratories.
BACKGROUND Laboratory tests to assess novel oral anticoagulants (NOACs) are under evaluation. Routine monitoring is unnecessary, but under special circumstances bioactivity assessment becomes crucial. We analyzed the effects of NOACs on coagulation tests and the availability of specific assays at different laboratories. METHODS Plasma samples spiked with dabigatran (Dabi; 120 and 300 μg/L) or...
متن کاملThe new oral anticoagulants and the future of haemostasis laboratory testing
The tests currently employed within most haemostasis laboratories to monitor anticoagulant therapy largely comprise the prothrombin time (PT)/ International Normalised Ratio (INR) and the activated partial thromboplastin time (APTT). These are respectively used to monitor Vitamin K antagonists (VKAs) such as warfarin, and unfractionated heparin. Additional tests that laboratories may also emplo...
متن کاملStandardizing global gene expression analysis between laboratories and across platforms
To facilitate collaborative research efforts between multiinvestigator teams using DNA microarrays, we identified sources of error and data variability between laboratories and across microarray platforms, and methods to accommodate this variability. RNA expression data were generated in seven laboratories, which compared two standard RNA samples using 12 microarray platforms. At least two stan...
متن کامل