Comparative study of cochlear damage with three perimodiolar electrode designs.
نویسندگان
چکیده
OBJECTIVE To describe intracochlear insertion trauma caused by three perimodiolar cochlear implant electrodes. STUDY DESIGN Descriptive histological study of 15 human cadaver temporal bones. METHODS Fifteen cadaver temporal bones underwent surface preparation and were implanted with one of the following perimodiolar electrode arrays: Combi 40+PM (MedEl Corporation), HiFocus II (Advanced Bionics Corporation), or Contour (Cochlear Corporation). A cryosectioning technique was used to study horizontal sections at 200 microm intervals with the electrode in place. Image-enhanced videofluoroscopy and computer-assisted morphometrics were used to assess the mechanism of insertion trauma and to determine electrode position within the modiolus. RESULTS Histological examination revealed varying degrees of damage to the spiral ligament, basilar membrane, and osseous spiral lamina. Using a novel grading system for electrode trauma, there was no statistically significant difference among the three electrodes. A literature search of histological studies of a commonly used "standard" electrode showed damage equal to or greater than that seen in the current study. CONCLUSIONS Insertion trauma caused by periomodiolar electrodes occurs to an acceptable degree. Refinement of electrodes based on mechanisms of trauma may be able to further reduce damage.
منابع مشابه
Comparison of electrode position in the human cochlea using various perimodiolar electrode arrays.
OBJECTIVE This study was conducted to evaluate the insertion properties and intracochlear trajectories of three perimodiolar electrode array designs and to compare these designs with the standard Cochlear/Melbourne array. BACKGROUND Advantages to be expected of a perimodiolar electrode array include both a reduction in stimulus thresholds and an increase in dynamic range, resulting in a more ...
متن کاملRadiological and Histological Evaluation of Perimodular Electrodes: Impact on Cochlear Implant Development
Introduction: Different Perimodiolar electrodes were developed by many cochlear implant (CI) manufacturers in the past few years. Possible advantages are lower stimulation thresholds and a better channel separation. A position close to the modiolus can be facilitated by different means: preformed electrode shape (Nucleus ContourTM electrode, Cochlear Corp., Australia), additional positioning el...
متن کاملPerimodiolar electrode position: Effects on thresholds, comfort levels, impedance measurements, and neural response telemetry
OBJECTIVE: This multicenter study describes the effects of perimodiolar electrode position on 50 adult patients (31 with an implanted Nucleus 24 Contour perimodiolar hugging electrode array [Cochlear Limited, Lane Cove, NSW, Australia] and 19 with an implanted straight electrode array) with a severe-to-profound sensorineural hearing loss. MATERIALS AND METHODS: In all patients, intraoperative i...
متن کاملThe contour electrode array: safety study and initial patient trials of a new perimodiolar design.
OBJECTIVE The aim of these studies was to investigate the insertion properties and safety of a new intracochlear perimodiolar electrode array design (Contour). BACKGROUND An electrode array positioned close to the neural elements could be expected to reduce stimulation thresholds and might potentially reduce channel interaction. METHODS Two sequential studies were conducted. In study 1, the...
متن کاملDevelopment and evaluation of the modiolar research array – multi-centre collaborative study in human temporal bones
OBJECTIVE Multi-centre collaborative study to develop and refine the design of a prototype thin perimodiolar cochlear implant electrode array and to assess feasibility for use in human subjects. STUDY DESIGN Multi-centre temporal bone insertion studies. MATERIALS AND METHODS The modiolar research array (MRA) is a thin pre-curved electrode that is held straight for initial insertion with an ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Laryngoscope
دوره 113 3 شماره
صفحات -
تاریخ انتشار 2003