The effect of perturbations on resistance to sliding in second-order moments comparing two different bracket types
نویسندگان
چکیده
Orthodontic literature has shown all ligation methods to behave similarly in the clinical situation; however, the reasoning behind this still requires further investigation. A novel frictional device able to measure forces at the level of the bracket along with a custom perturbation device was used to investigate the effect of perturbations on resistance to sliding (RS) using conventional and passive ligated brackets. 150 3M Victory Series twins (0.022 slot) and 150 Damon Q brackets (0.022 slot) were tested using an 0.018 x 0.025 stainless steel wire for RS. There were 5 test groups consisting of equal numbers (n=30) representing combinations of high and low amplitude and frequency of perturbations along with a control. Second order angulation tested ranged from 0 to 6 degrees. Results for conventional brackets in the presence of perturbations at 0 degrees showed there was a statistically significant reduction (P<0.001) in RS when compared to controls. At 6 degrees, this difference (P<0.001) was seen in both high perturbation groups and one of the low perturbation groups. For passive ligated brackets, no statistically significant difference between groups was seen at 0 degrees. However, at 6 degrees high perturbation groups both resulted in statistically significant (P<0.001) reductions in RS when compared to controls. From this study it was concluded that passive ligated brackets have a lower RS when compared to conventional ligated brackets under all test conditions and angulations. Also, amplitude of perturbations has a larger role than frequency in reduction of RS values.
منابع مشابه
Effect of CO2 laser irradiation on the surface of the polycrystalline ceramic bracket and the rate of canine movement with sliding mechanic
Introduction: Metal brackets are the most commonly used brackets in clinical orthodontics, but the sight of color of the metal bracket can be unpleasant for some patients. Ceramic brackets offer the desired beauty but they have higher frictional resistance. Considering that in vitro studies suggest that CO2 laser reduces the friction between the wire and slot of the bracket in the sliding mech...
متن کاملبررسی مقاومت اصطکاکی سیم نیکل تیتانیوم ارتودنسی در زوایای مختلف قرارگیری براکت و سیم
Background and Objective: Resistance to sliding is a combination of friction and binding. When the angle between the bracket and the wire exceeds the critical angle, binding occurs. The influence of angulation is confounding because of certain inherent physical characteristics of materials. The present study was carried out to evaluate the effect of wire- bracket angulation on resistance to sli...
متن کاملEnamel Surface Roughness after Orthodontic Bracket Debonding and Composite Resin Removal by Two Types of Burs
Objective: Increased enamel surface roughness following orthodontic bracket debonding leads to increased plaque accumulation and enamel decalcification. Therefore, different methods are employed to achieve smoother enamel surfaces after bracket debonding. This study compared enamel surface roughness following orthodontic bracket debonding and composite resin removal using white stone and tung...
متن کاملEvaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study
Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...
متن کاملInfluence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study
OBJECTIVE To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. METHODS Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archw...
متن کامل