Analytical performance, agreement and user-friendliness of five C-reactive protein point-of-care tests.

نویسندگان

  • Margaretha C Minnaard
  • Alma C van de Pol
  • Berna D L Broekhuizen
  • Theo J M Verheij
  • Rogier M Hopstaken
  • Sanne van Delft
  • Antoinette M J Kooijman-Buiting
  • Joris A H de Groot
  • Niek J De Wit
چکیده

BACKGROUND Point-of-care (POC) C-reactive protein (CRP) testing is increasingly used in primary care to assist general practitioners (GPs) in the diagnostic workup for various complaints. The present study compares analytical performance, agreement and user-friendliness of five of these POC CRP tests. METHODS The following five POC CRP tests were evaluated: Afinion and NycoCard Reader II (both Alere), Eurolyser Smart 700/340 (Eurolyser), QuikRead go and QuikRead 101 (both Orion Diagnostica). Results were compared with those of a standard immunoturbidimetric method performed on a routine analyzer (Olympus AU 2700, Beckman Coulter). Analytical performance and agreement with the laboratory standard for the five different POC tests were analyzed. Subsequently, user-friendliness of the POC tests was assessed. RESULTS Within-day CVs varied from 2.6% (QuikRead go) to 19.4% (Eurolyser Smart 700/340) for low CRP values (< 20 mg/L), and 1.1% (QuikRead go) to 17.5% (Eurolyser Smart 700/340) for high values (> 100 mg/L). Between-day CVs varied from 4.6% (Afinion) to 30.5% (Eurolyser Smart 700/340) for low values and 4.0% (QuikRead go) to 18.0% (Eurolyser Smart 700/340) for high values. With high CRP values (> 100 mg/L) agreement with the laboratory standard systematically decreased for all POC tests. Regarding user-friendliness Afinion and Eurolyser Smart 700/340 were judged easiest to operate. CONCLUSIONS Analytical performance, agreement, and user-friendliness of the POC CRP tests varied considerably, yet overall four devices showed adequate analytical performance and agreement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analytical performance, agreement and user-friendliness of six point-of-care testing urine analysers for urinary tract infection in general practice

OBJECTIVE Various point-of-care testing (POCT) urine analysers are commercially available for routine urine analysis in general practice. The present study compares analytical performance, agreement and user-friendliness of six different POCT urine analysers for diagnosing urinary tract infection in general practice. SETTING All testing procedures were performed at a diagnostic centre for pri...

متن کامل

Diagnostic accuracy and user-friendliness of 5 point-of-care D-dimer tests for the exclusion of deep vein thrombosis.

BACKGROUND Point-of-care D-dimer tests have recently been introduced to enable rapid exclusion of deep venous thrombosis (DVT) without the need to refer a patient for conventional laboratory-based D-dimer testing. Before implementation in practice, however, the diagnostic accuracy of each test should be validated. METHODS We analyzed data of 577 prospectively identified consecutive primary ca...

متن کامل

Accuracy and Feasibility of Point-Of-Care White Blood Cell Count and C-Reactive Protein Measurements at the Pediatric Emergency Department

BACKGROUND Several point-of-care (POC) tests are available for evaluation of febrile patients, but the data about their performance in acute care setting is sparse. We investigated the analytical accuracy and feasibility of POC tests for white blood cell (WBC) count and C-reactive protein (CRP) at the pediatric emergency department (ED). METHODS In the first part of the study, HemoCue WBC and...

متن کامل

An Investigation of the Effects of Aerobic Exercise on Serum Brain Natriuretic Peptide and C-Reactive Protein in women with Cardiovascular Diseases

Introduction: The aim of this study was to evaluate the effects of aerobic exercise on brain natriuretic peptide (BNP) and C-reactive protein (CRP) levels in women with cardiovascular diseases. Materials and Methods: In this semi experimental study, thirty female patients with at least one coronary artery stenosis (more than70%) were chosen and divided into two groups of aerobic training (n=15)...

متن کامل

Immediate Diagnosis of Early Onset Sepsis in Premature Newborns by Measurement of Cord C-Reactive Protein and Interleukin-6

Background: The purpose of this study was to determine the relationship between early onset sepsis and increased levels of C-reactive protein (CRP) and interleukin-6 (IL-6) in cord plasma. Methods: A prospective study was conducted in 141 premature infants delivered with gestational ages of 26-35 weeks. IL-6 and CPR were measured by enzyme-linked immunoassay in the cord plasma of the neonates. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Scandinavian journal of clinical and laboratory investigation

دوره 73 8  شماره 

صفحات  -

تاریخ انتشار 2013