Review Article: Polyethylene wear and osteolysis in total hip arthroplasty.

نویسندگان

  • Y H Zhu
  • K Y Chiu
  • W M Tang
چکیده

Polyethylene wear has been accepted as a major cause of osteolysis in total hip arthroplasty. Submicron particles, which are secondary to abrasive wear, migrate into the effective joint space and stimulate a foreign-body response resulting in bone loss which is mainly mediated by macrophages. Diagnosis depends on serial radiographic evaluation and frequent follow-up. Polyethylene wear and osteolysis can be prevented by reducing the wear such as using a small femoral head, adaptive polyethylene thickness, suitable surgical techniques, non-polyethylene articulation, etc. The presence of cement or circumferential coatings may also retard the distal migration of particles. Medicines such as NSAIDs and bisphosphonate appear to inhibit the progress of osteolysis. As far as treatment, revision surgery is able to reconstruct the joint by replacing partial or total prosthesis and repair the defect by bone grafting according to intraoperative assessment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cross-linked polyethylene and bisphosphonate therapy for osteolysis in total hip arthroplasty: a case report.

A 39-year-old woman underwent bilateral total hip arthroplasty with conventional, ethylene oxide-sterilised liners when she was a subject in a radiostereometric analysis study. Within 2 years she had rapid polyethylene wear with aggressive, asymptomatic, and periprosthetic osteolysis on both sides. Oral alendronate therapy halted the progression of osteolysis over a year and revision to cross-l...

متن کامل

Failure of a metal-on-metal total hip arthroplasty from progressive osteolysis.

Ultra-high-molecular weight polyethylene (UHMWPE) wear, debris-induced osteolysis is a frequent cause of failure of total hip arthroplasty. Metal-on-metal total hip arthroplasty eliminates the generation of UHMWPE particulate debris. Although the volumetric wear of a metal-on-metal articulation may be lower than a metal-UHMWPE articulation, the number of particles may be higher. Osteolysis can ...

متن کامل

In Vivo Wear Particles of Annealed Highly Cross-Linked Polyethylene in Total Hip Arthropalsty

INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...

متن کامل

Cross-linked versus conventional polyethylene for total hip replacement: a meta-analysis of randomised controlled trials.

We conducted a systematic review and meta-analysis of randomised controlled trials comparing cross-linked with conventional polyethylene liners for total hip replacement in order to determine whether these liners reduce rates of wear, radiological evidence of osteolysis and the need for revision. The MEDLINE, EMBASE and COCHRANE databases were searched from their inception to May 2010 for all t...

متن کامل

In Vivo Wear Particles of Remelted Highly Cross-Linked Polyethylene in Total Hip Arthropalsty

INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 2001