A post-processing technique to remove background noise from echo integration data

نویسندگان

  • Jonathan L. Watkins
  • Andrew S. Brierley
چکیده

Echo integration of biological organisms with a low target strength can be difficult because of the problem of setting suitable pre-integration thresholds, and this is particularly acute with higher frequencies, such as 120 or 200 kHz, which are often used in studies of euphausiids. One solution is to integrate data without any threshold and then remove background noise during post-processing. Unthresholded, integrated data of micronekton and Euphausia superba collected with a SIMRAD EK500 at frequencies of 38 and 120 kHz are presented. The underlying background noise level follows a 20 log R+2áR relationship, which can be scaled to the minimum volume backscatter (Sv) in each layer during a transect and then subtracted from the entire data set to remove background noise. The utility of this procedure is demonstrated by making comparisons of Sv at each frequency and investigating the effect of noise removal on the identification of targets based on the dB difference (120 kHz Sv–38 kHz Sv).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

متن کامل

An Echo Canceller Robust to Noise and Residual Echo

When we talk with hands-free in a car or noisy lobby, the performance of the echo canceller degrade because background noise added to echo caused by the distance from mouth to microphone is relatively long. It gives a reason for necessity of noise-robust and high convergence speed adaptive algorithm. And if acoustic echo canceller operated not perfectly, residual signal going through the echo c...

متن کامل

Adaptive-Filtering-Based Algorithm for Impulsive Noise Cancellation from ECG Signal

Suppression of noise and artifacts is a necessary step in biomedical data processing. Adaptive filtering is known as useful method to overcome this problem. Among various contaminants, there are some situations such as electrical activities of muscles contribute to impulsive noise. This paper deals with modeling real-life muscle noise with α-stable probability distribution and adaptive filterin...

متن کامل

Pervasive white and colored noise removing from magnetotelluric time series

Magnetotellurics is an exploration method which is based on measurement of natural electric and magnetic fields of the Earth and is increasingly used in geological applications, petroleum industry, geothermal sources detection and crust and lithosphere studies. In this work, discrete wavelet transform of magnetotelluric signals was performed. Discrete wavelet transform decomposes signals into c...

متن کامل

Effect of Physiological noise on Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field

Introduction: Functional MRI methods have been used to study sensorimotor processing in the brain and the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as signifi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1996