Postoperative wavefront analysis and contrast sensitivity of a multifocal apodized diffractive IOL (ReSTOR) and three monofocal IOLs.
نویسندگان
چکیده
PURPOSE To compare visual acuity, total and high order wavefront aberrations (coma, spherical aberration, and other terms of high order aberration), and contrast sensitivity in 105 eyes implanted with 4 different types of intraocular lenses (IOLs) (1 multifocal apodized diffractive IOL and 3 monofocal IOLs). METHODS A prospective study comparing four types of IOLs (Alcon ReSTOR [50 eyes], Alcon Acrysof MA30AC [20 eyes], Alcon Acrysof SA60AT [20 eyes], and Mediphacos Acqua IOL [15 eyes]) was carried out. All eyes were targeted for emmetropia. Complete ophthalmological examination, including uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), contrast sensitivity (Pelli-Robson chart), and wavefront analysis, was performed 2 months postoperatively. RESULTS All eyes in all groups had BSCVA > or = 20/32 postoperatively. Mean total aberration root-mean-square (RMS) values were: 0.72 +/- 0.25 microm (ReSTOR), 0.94 +/- 0.26 microm (MA30), 0.84 +/- 0.23 microm (SA60), and 2.04 +/- 0.77 microm (Acqua). Mean higher order aberration values were: 0.35 +/- 0.15 microm (ReSTOR), 0.41+/- 0.12 microm (MA30), 0.43 +/- 0.13 microm (SA60), and 0.85 +/- 0.50 microm (Acqua). The Acqua IOL showed statistically significant more total and higher order aberrations when compared with the other IOLs (P < .05). The ReSTOR IOL showed statistically significant less induction of spherical aberration when compared to the monofocal IOLs (P < .05). Mean contrast sensitivity values were: 1.64 +/- 0.08 (ReSTOR), 1.72 +/- 0.08 (MA30), 1.70 +/- 0.07 (SA60), and 1.65 +/- 0.11 (Acqua). CONCLUSIONS Different types of IOLs resulted in measurably different postoperative higher order aberration patterns. The multifocal apodized diffractive IOL (ReSTOR) induced significantly less spherical aberration compared to the monofocal IOLs. Contrast sensitivity revealed better values with MA30 and SA60 IOLs when compared to ReSTOR. The integration of wavefront technology in evaluating pseudophakic patients represents a step towards better understanding and analyzing postoperative visual quality.
منابع مشابه
Comparative visual performance with monofocal and multifocal intraocular lenses
BACKGROUND To compare near, intermediate, and distance vision, and quality of vision using appropriate subjective questionnaires, when monofocal or apodized diffractive multifocal intraocular lenses (IOLs) are binocularly implanted. METHODS Patients with different binocular IOLs implanted were recruited after surgery and had their visual acuity tested, and quality of vision evaluated, at a si...
متن کاملVisual performance of Acrysof ReSTOR compared with a monofocal intraocular lens following implantation in cataract surgery
The aim of this study was to compare the visual performance of Acrysof ReSTOR and Acrysof Natural intraocular lenses (IOLs) following cataract surgery. A randomized prospective study was performed in which 64 eyes (51 patients) were divided randomly into two groups. Monofocal IOLs (Acrysof Natural) were implanted into 34 eyes (27 patients) and multifocal IOLs (Acrysof ReSTOR) were implanted int...
متن کاملVisual acuity and contrast sensitivity: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lenses.
PURPOSE To compare the visual acuity and contrast sensitivity in eyes with the AcrySof ReSTOR multifocal intraocular lens (IOL) (Alcon) and eyes with the monofocal AcrySof SA60AT IOL. SETTING Policlinico Umberto I, Department of Ophthalmology, Rome, and private clinical practice, Rome, Italy. METHODS One hundred eyes had phacoemulsification cataract extraction and implantation of a ReSTOR m...
متن کاملComparison of outcomes with multifocal intraocular lenses: a meta-analysis
PURPOSE To compare the clinical outcome of different multifocal intraocular lenses (IOLs) based on information reported in the international literature. METHODS All comparative clinical trials that involved implanting at least one multifocal IOL in patients with cataract or presbyopia were extracted from the literature. Clinical outcomes included uncorrected near visual acuity, uncorrected di...
متن کاملEvaluation of rotation and visual outcomes after implantation of monofocal and multifocal toric intraocular lenses.
PURPOSE To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). METHODS A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of refractive surgery
دوره 21 6 شماره
صفحات -
تاریخ انتشار 2005