Glucosuria: accuracy and precision of laboratory diagnosis by dip stick analysis.

نویسندگان

  • G P James
  • D E Bee
چکیده

Two urine dip-stick assays for glucose were studied and compared to a quantitative hexokinase procedure. We determined sensitivity, specificity, predictive value of "normal" and "abnormal" dip stick results, assay efficiency, technologist precision, and method association. Precision was poor. Attempts to estimate urine glucose concentration with the dip sticks frequently produced gross inaccuracies. We believe the dip stick glucose assay should be considered qualitative only; as a qualitative test, the dip sticks are fairly efficient at distinguishing glucose concentrations of less than 0.3 g/L from concentrations greater than 0.3 g/L.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemoglobinuria and hematuria: accuracy and precision of laboratory diagnosis.

Five methods of assessing blood in urine were studied and compared: sedimentation count, hemacytometry, "Clini-lab" reagent strip and "N-Multistix" and "ChemStrip-8" dipsticks. The minimum sensitivity of two commercially available urine dip-stick procedures for blood was established. The study includes method association, assay variation among and within technologists, accuracy, precision, and ...

متن کامل

Evaluation of accuracy, precision and consensus of four laboratory glucose measurement kits with reference method

Abstract         Background and Objective: According to recent changes in diagnostic criteria for diabetes, the harmonization of results obtained from various methods and systems by considering their accuracy and precision is essential. This study aimed to evaluate the accuracy, precision and consensus of some routine laboratory glucose kits in co...

متن کامل

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

HPTLC-Densitometric Determination of Cetirizine and Montelukast Analysis in Combined Tablet Dosage Forms

A simple, accurate and rapid high performance thin layer chromatography (HPTLC)-densitometric method was developed for separation and determination of cetirizine (CET) as a long acting antihistamine and montelukast (MON) as an antileukotriene in pharmaceutical dosage forms. The compounds were separated on silica gel 60 F254 HPTLC plates using a mixture of ethyl acetate : methanol : ammonia solu...

متن کامل

HPTLC-Densitometric Determination of Cetirizine and Montelukast Analysis in Combined Tablet Dosage Forms

A simple, accurate and rapid high performance thin layer chromatography (HPTLC)-densitometric method was developed for separation and determination of cetirizine (CET) as a long acting antihistamine and montelukast (MON) as an antileukotriene in pharmaceutical dosage forms. The compounds were separated on silica gel 60 F254 HPTLC plates using a mixture of ethyl acetate : methanol : ammonia solu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 1979