Analysis of Surface Characteristics of ProTaper Universal and ProTaper Next Instruments by Scanning Electron Microscopy
نویسندگان
چکیده
BACKGROUND Many new rotary files systems have been introduced, however, limited research has been conducted related to the surface irregularities of these files and if these have any effects on the files themselves. Hence, the aim of the present study was to analyze surface irregularities of the ProTaper® Universal rotary files (PTU) and the ProTaper Next™ rotary files (PTN) before and after instrumentation in curved canals. The main objective was to investigate the nature of these irregularities and how they might influence the use and fracture of rotary files during root-canal treatments. MATERIAL AND METHODS The files were examined pre-operatively using a stereomicroscope and scanning electron microscopy(SEM) to analyze surface imperfections and the presence of particles. Mesial roots of forty extracted mandibular molars were selected. Each instrument was used to prepare one of the mesial canals. The files were then rinsed with alcohol, and autoclaved and analyzed again. RESULTS Of the 80 files used in this study, five files fractured, five files unwound and seven files were curved or bent and they all belonged to the PTU group. Irregularities and debris could be visualized with the SEM on both unused PTU and PTN files. Most of the debris was found associated with deeper milling grooves and defects on the surface of the metal. Surface analysis of the files that were used and sterilized were performed and the SEM images demonstrated organic debris, metal flash, and crack formation and initiation of fractures for both file types. All files showed machining grooves, metal flash, debris, and defects on cutting edges. CONCLUSIONS These irregularities appear to be critical in the accumulation of debris and initiation of fatigue and crack propagation within the NiTi alloy. The accumulation of debris could be a concern due to the potential exchange of organic debris between patients. Key words:ProTaper® Universal, ProTaper Next™, surface characteristics, SEM.
منابع مشابه
Cyclic fatigue resistance of two nickel-titanium instruments in different curving angles: a comparative study.
The cyclic resistance of ProTaper Universal (size 25/08) and ProTaper Next (size 25/06) instruments was compared in artificial canals with different curvatures in this study. A total of 30 ProTaper Universal and 30 ProTaper Next instruments were divided into 6 groups (n = 10) and were operated into artificial canals with 3 different angles of curvature (45°, 60°, 90°). The canal length was kept...
متن کاملComparison of WaveOne and ProTaper Universal Preparation Systems in the Amount of Smear Layer/Debris Production: an in-vitro SEM Study
Background and Aim: Debris and the smear layer that remain after root canal preparations may result in failure of root canal therapies. The aim of this study was to compare the smear layer formation and the amount of residual debris following the use of WaveOne and ProTaper rotary files in mesiobuccal root canals of upper first molars by scanning electron microscopy (SEM). Materials and Method...
متن کاملDefects in nickel-titanium instruments after clinical use. Part 5: single use from endodontic specialty practices.
INTRODUCTION Single use of endodontic nickel-titanium (NiTi) instruments has been recommended to reduce instrument fatigue and the possibility of cross-contamination. The purpose of this study was to evaluate the defects of three NiTi rotary systems (ProFile series 29 [Dentsply Tulsa Dental Products, Tulsa, OK], ProFile [Dentsply Tulsa Dental Products], and ProTaper [Dentsply Maillefer, Ballaig...
متن کاملAn in vitro comparison of apically extruded debris and instrumentation times with ProTaper Universal, ProTaper Next, Twisted File Adaptive, and HyFlex instruments.
INTRODUCTION The purpose of this study was to compare the in vitro amount of apically extruded debris with new endodontic rotary nickel-titanium instruments. METHODS Sixty mandibular premolars were instrumented up to size 25 using ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland), ProTaper Next (Dentsply Maillefer), Twisted File Adaptive (SybronEndo, Orange, CA), and HyFlex (Co...
متن کاملStereomicroscopic Evaluation of Radicular Dentinal Defects after Using EDTA Gel with Different Rotary Systems: An In-Vitro Study
The purpose of the present study was to study the occurrence of radicular dentinal defects after using EDTA gel during preparation of the root canal with ProTaper Universal (Dentsply Maillefer, Switzerland), HyFlex (ColteneWhaledent, Allstetten, Switzerland), and ProTaper Next (Dentsply Maillefer) rotary instruments. Forty-eight single rooted premolars were selected. Twelve teeth were instrumen...
متن کامل