An investigation into the use of MMCTP to tune accelerator source parameters and testing its clinical application

نویسندگان

  • Elaine Conneely
  • Andrew Alexander
  • Gabriella Stroian
  • Jan Seuntjens
  • Mark J. Foley
چکیده

This paper presents an alternative method to tune Monte Carlo electron beam parameters to match measured data using a minimal set of variables in order to reduce the model setup time prior to clinical implementation of the model. Monte Carlo calculations provide the possibility of a powerful treatment planning verification technique. The nonstandardized and nonautomated process of tuning the required accelerator model is one of the reasons for delays in the clinical implementation of Monte Carlo techniques. This work aims to establish and verify an alternative tuning method that can be carried out in a minimal amount of time, allowing it to be easily implemented in a clinical setting by personnel with minimal experience with Monte Carlo methods. This tuned model can then be incorporated into the MMCTP system to allow the system to be used as a second dose calculation check for IMRT plans. The technique proposed was used to establish the primary electron beam parameters for accelerator models for the Varian Clinac 2100 6 MV photon beam using the BEAMnrc Monte Carlo system. The method is intended to provide a clear, direct, and efficient process for tuning an accelerator model using readily available clinical quality assurance data. The tuning provides a refined model, which agrees with measured dose profile curves within 1.5% outside the penumbra or 3 mm in the penumbra, for square fields with sides of 3 cm up to 30 cm. These models can then be employed as the basis for Monte Carlo recalculations of dose distributions, using the MMCTP system, for clinical treatment plans, providing an invaluable assessment tool. This was tested on six IMRT plans and compared to the measurements performed for the pretreatment QA process. These Monte Carlo values for the average dose to the chamber volume agreed with measurements to within 0.6%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Systematic and comprehensive analysis of the dose-response characteristics of a morning quality check of a linear accelerator and an important application of accelerator performance prediction

Background: This paper aimed to analyze the output constancy of a medical linear accelerator using PTW QUICKCHECKwebline and studied the sensitivity of the PTW QUICKCHECKwebline. Materials and Methods:  The paper statistically analyzed the output doses of 6 MV and 10 MV of photons and 6 MeV, 9 MeV, and 12 MeV of electrons from a medical linear accelerator measured before the daily treatment to ...

متن کامل

A Preliminary Investigation into Geometry, Represented by Parameters, and its Effect on Function and Manufacturing Attributes

  This paper demonstrates a preliminary investigation of geometry, function and its relation to DFX principles, namely DFM (Design for Manufacturing). This is the starting point for research on the development of an expert system that assesses design goals along DFX principles in a feature-based CAD environment. There is a need for a deeper level of understanding of the relationship between geo...

متن کامل

Experimental Investigation of Physical and Chemical Properties of Drilling Foam and Increasing its Stability

This investigation presents the effect of various parameters on foam stability and its rheological properties. The underlying idea of this experiment is generating of drilling foam with uniform bubbles. The main problem of foam using is controlling its stability during field application. The most important parameters which cause Instability in foam are gravity drainage, gas diffusion and bu...

متن کامل

Investigations of parameters affecting the photon energy spectra of an 18 MV Varian 2100C/D linear accelerator

Radiotherapy using linear accelerators is known as an effective modality for cancer treatment. The photons energy of treatment beams significantly affect the dose distribution. Therefore, it is important to accurately evaluate the photon energy spectra. In this study, MCNPX Monte Carlo code (version 2.6.0) was used to simulate an 18 MV photon beam of a Varian 2100C/D linear accelerator. By matc...

متن کامل

Performance Investigation of Pentacene Based Organic Double Gate Field Effect Transistor and its Application as an Ultrasensitive Biosensor

In this paper, the electrical performance of double gate organic field effecttransistor (DG-OFET) are thoroughly investigated and feasibility of the deviceas an efficient biosensor is comprehensively assessed. The introduced deviceprovides better gate control over the channel, yielding better charge injectionproperties from source to channel and providing higher on-state...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013