Ventricular assist device in severe heart failure: effects on cytokines, complement and body weight.

نویسندگان

  • A L Clark
  • M Loebe
  • E V Potapov
  • K Egerer
  • C Knosalla
  • R Hetzer
  • S D Anker
چکیده

AIMS Inflammatory and immune activation and body wasting are important features of end-stage chronic heart failure. It is not known whether restoration of cardiac output by assist device implantation can improve these abnormalities. METHODS We studied 48 patients (39 males; age 45+/-2 years) with NYHA class IV heart failure. All patients underwent ventricular assist device implantation for end-stage heart failure as a bridge to cardiac transplantation. Plasma levels of tumour necrosis factor alpha, and its receptors, interleukin-6, elastase, activated complement, and soluble CD14 receptors were measured at the time of operation and in survivors at 1 week (n=46), 40 days (n=35) and 90 days (n=26). Follow-up was for a minimum of 1 year. RESULTS One-year survival was 35% (95% CI: 22-49%). Body mass index was the only predictor of survival (body mass index >25 (n=16); survival 63 (39-86) %; body mass index <25 (n=32); survival 22 (7.5-36) %: P=0.003). Tumour necrosis factor alpha fell from 9.66+/-1.33 pg x ml(-1) to 4.2+/-1.0 at 1 week (P=0.008), but returned to pre-operative levels at 90 days. Interleukin-6, activated complement and elastase fell progressively to 40 days, but were rising at 90 days. There was no change in tumour necrosis factor receptor. There was a gradual rise in CD14 (3.99+/-0.15 microg x ml(-1) at baseline, 5.02+/-0.39 at 90 days, P=0.006). After surgery, body weight fell from 80+/-2 to 73+/-2 kg by 1 month (P<0.001) and to 72+/-2 kg at 90 days. CONCLUSIONS Ventricular assist device implantation results in a short-term fall in tumour necrosis factor alpha and interleukin-6, but no change in CD14 or tumour necrosis factor receptor, suggesting that the pathophysiological process resulting in inflammation was not altered by left ventricular assist device implantation. Low body mass index is related to poor outcome after assist device implantation, and no weight gain.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Combined Ventricular Assist Device Placement With Adjustable Gastric Band (VAD-BAND): A Promising New Technique for Morbidly Obese Patients Awaiting Potential Cardiac Transplantation

BACKGROUND Morbid obesity remains a potential relative contraindication for cardiac transplantation. Hence, a select population of morbidly obese patients with end-stage heart failure may require a ventricular assist device (VAD) as a bridge to transplantation to afford them time to lose sufficient weight and thus decrease there mortality rate after transplantation. Unfortunately, obtaining sui...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Left Ventricular Dilatation Increases the Risk of Ventricular Arrhythmias in Patients With Reduced Systolic Function

BACKGROUND Reduced left ventricular (LV) ejection fraction increases the risk of ventricular arrhythmias; however, LV ejection fraction has a low sensitivity to predict ventricular arrhythmias. LV dilatation and mass may be useful to further risk-stratify for ventricular arrhythmias. METHODS AND RESULTS Patients from the Genetic Risk of Assessment of Defibrillator Events (GRADE) study (N=930)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 22 24  شماره 

صفحات  -

تاریخ انتشار 2001