Microbicidal efficacy of povidone-iodine in a noncontact manner applied to a continuous ambulatory peritoneal dialysis connection system.

نویسندگان

  • Tetsuya Kashiwagi
  • Yasuhiko Iino
  • Hideyasu Miyahara
  • Yasuo Katayama
چکیده

In peritoneal dialysis (PD) the dialysate is introduced into the peritoneal cavity, and the peritoneal membrane is used as the dialysis membrane. In PD, patients exchange the dialysate by themselves through the connection tube attached to the indwelling catheter that is inserted into the peritoneal cavity. Microbes may enter the peritoneal cavity during dialysate exchange, and, therefore, peritonitis is a potential complication of PD. To prevent microbial contamination, the connection tube tip is generally sealed with a protection cap containing povidone-iodine (PVP-I) during the dwelling time. This cap is designed to make direct contact with the tube tip so that microbes attached during dialysate exchange are killed by the next dialysate exchange. However, if excess PVP-I flows into the peritoneal cavity and is absorbed into the body, the complications, including thyroid dysfunction, peritoneal inflammation, and fibrous thickening, can develop. Therefore, in this study, a new manual connection system (Zero System, JMS Co., Ltd., Hiroshima, Japan) for continuous ambulatory peritoneal dialysis was investigated to confirm that the PVP-I solution within the protection cap of the new system would not flow into the fluid passing through the tube. An experiment was also performed to confirm that the microbes on the connector tip become completely nonviable after attachment of the cap for 3 hours. The cap is fitted with a sponge containing a 10% PVP-I solution, the same as for the conventional cap system. However, the system is designed to achieve disinfection without contact, unlike with the conventional system, in which disinfection is achieved by direct contact of the PVP-I-containing sponge with the open end of the attached connector. The test results demonstrated that adequate disinfection with this system can be achieved by the next exchange, while avoiding entry of PVP-I into the peritoneal cavity from the cap. The results suggest that the use of this connection system can avoid adverse reactions arising from the absorption of PVP-I and prevent the onset of peritonitis caused by microbial invasion of the peritoneal cavity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between Ultrafiltration Coefficient and Effective Lymphatic Absorption Rate in Continuous Ambulatory Peritoneal Dialysis Patients: A Possible Paradigm Shift

Background: The relative contribution of transcapillary water movement and lymphatic reabsorption in peritoneal dialysis (PD) is a critical issue, particularly in patients with ultrafiltration failure (UFF). Based on routine results obtained from the PD Adequest 2.0 software, the present study aimed to re-evaluate the separate effects of transcapillary water movement and lymphatic reabsorption ...

متن کامل

Chronic exit-site care using povidone–iodine versus normal saline in peritoneal dialysis patients

Continuous ambulatory peritoneal dialysis is an important treatment method for patients with end-stage renal disease. Although the incidence of catheter-associated complications such as peritonitis and exit-site infection has been decreasing, these complications have not been resolved completely. Therefore, prevention of catheter-associated infections is essential both soon after peritoneal dia...

متن کامل

ارایه مدلی جهت پیش‌بینی بقای بیماران دیالیز صفاقی با استفاده از الگوریتم‌های داده‌کاوی

Background: Peritoneal dialysis is one of the most commonly used treatment methods for the patients with end stage renal failure. In recent years, the mortality rate of patients under this treatment has decreased; however, long-term survival is still an important challenge for health systems. The present study aimed to predict the survival of continuous ambulatory peritoneal dialysis patients. ...

متن کامل

Peritonitis prevented in continuous ambulatory peritoneal dialysis by using the Hong Kong connection.

Based on the hypothesis that air contamination is an important cause of peritonitis in continuous ambulatory peritoneal dialysis, a simple and cheap connection system was developed whereby a clear polyethylene bag containing an antiseptic gauze was used as a sterilising chamber, effectively enclosing the connection procedure. Seven modifications to the connection technique were introduced over ...

متن کامل

Allergic dermatitis caused by povidone iodine: an uncommon complication of chronic peritoneal dialysis treatment.

Allergic dermatitis around the catheter exit site, caused by topical antiseptics such as povidone iodine and chlorhexidine gluconate, is an uncommon complication in patients on chronic peritoneal dialysis (CPD). As yet, published reports concerning this rare non catheter-related complication are few. The frequency of this type of dermatitis is not known, because reports of isolated cases consti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Nippon Medical School = Nippon Ika Daigaku zasshi

دوره 77 2  شماره 

صفحات  -

تاریخ انتشار 2010