Normal values of exhaled carbon monoxide in healthy subjects: comparison between two methods of assessment
نویسندگان
چکیده
BACKGROUND In a previous study, exhaled carbon monoxide (eCO) has been assessed in healthy non-smokers with a photo acoustic spectrometer Brüel&Kjær 1312. Unexpectedly, values were higher than those reported in literature, which were mostly obtained with electrochemical analysers. This study was aimed to compare eCO values obtained with Brüel&Kjær 1312 and PiCO + Smokerlyzer, a largely utilized electrochemical analyser. METHODS Thirty-four healthy subjects, 15 non-smokers and 19 smokers, underwent eCO assessment with Brüel&Kjær 1312 and PiCO + Smokerlyzer during a prolonged expiration (15 seconds). Brüel&Kjær 1312 assessed CO concentration 7 and 12 seconds after the beginning of expiration and displayed the mean value. PiCO + Smokerlyzer was utilized according to the manufacturer's recommendations. In vitro, the two devices were tested with standard concentrations of CO in nitrogen (5, 9.9, 20, and 50 ppm), and the time needed by PiCO + Smokerlyzer readings to stabilize was assessed at different gas flows. RESULTS Both Brüel&Kjær 1312 and PiCO + Smokerlyzer presented very good internal consistency. The values provided were strictly correlated, but at low test concentrations, the Brüel&Kjær 1312 readings were greater than the PiCO + Smokerlyzer, and vice versa. PiCO + Smokerlyzer overestimated the CO standard concentrations at 5 and 9.9 ppm by 20%, while Brüel&Kjær 1312 measures were correct. PiCO + Smokerlyzer readings stabilized in 12 seconds during in vitro tests and in 15 seconds during in vivo measurements, suggesting that the values displayed corresponded to the initial phase of expiration. CONCLUSIONS Differences between Brüel&Kjær 1312 and PiCO + Smokerlyzer may be explained because Brüel&Kjær 1312 measured CO levels in the middle and at the end of expiration while PiCO + Smokerlyzer assessed them in the initial part of expiration.
منابع مشابه
منوکسید کربن بازدمی دانش آموزان تهران
Background and aimsCarbon monoxide poisoning is a major cause of mortality due to gasinhalation. It is more prevalent in winter, because of poor indoor ventilation. The purpose of ourstudy was to evaluate exhaled carbon monoxide of students and to estimate their exposure to this gas.MethodsThis cross-sectional study was performed in winter 2008. The exhaled carbonmonoxide level of 184 students ...
متن کاملIncreased carbon monoxide in exhaled air of subjects with upper respiratory tract infections.
Viral infection may induce the expression of heme oxygenase, resulting in increased carbon monoxide (CO) formation. CO may be produced by various cells of the upper and lower respiratory tract and may be detected in the exhaled air. Therefore, exhaled CO concentrations were measured on a CO monitor by vital capacity maneuver in subjects with upper respiratory tract infections (URTIs) and in non...
متن کاملThe measurement of exhaled carbon monoxide in healthy smokers and non-smokers.
The measurement of exhaled carbon monoxide (CO) level may provide an immediate, non-invasive method of assessing smoking status. The aims of this study were to use a portable CO monitor to compare the exhaled CO levels in established smokers and non-smokers. The exhaled CO levels were measured in 322 subjects (243 healthy smokers, 55 healthy non-smokers, 24 passive smokers) who applied to healt...
متن کاملEffects of acute hypoventilation and hyperventilation on exhaled carbon monoxide measurement in healthy volunteers
BACKGROUND High levels of exhaled carbon monoxide (eCO) are a marker of airway or lung inflammation. We investigated whether hypo- or hyperventilation can affect measured values. METHODS Ten healthy volunteers were trained to achieve sustained end-tidal CO2 (etCO(2)) concentrations of 30 (hyperventilation), 40 (normoventilation), and 50 mmHg (hypoventilation). As soon as target etCO(2) values...
متن کاملIncreased levels of exhaled carbon monoxide in bronchiectasis: a new marker of oxidative stress.
BACKGROUND Bronchiectasis is a chronic inflammatory lung disease associated with increased production of oxidants due mostly to neutrophilic inflammation. Induction of heme oxygenase (HO-1) by reactive oxygen species is a general cytoprotective mechanism against oxidative stress. HO-1 catabolises heme to bilirubin, free iron and carbon monoxide (CO). Exhaled CO measurements may therefore reflec...