Heterogeneous microinfarcts caused by coronary microemboli: evaluation with multidetector CT and MR imaging in a swine model.

نویسندگان

  • Marcus Carlsson
  • David Saloner
  • Alastair J Martin
  • Philip C Ursell
  • Maythem Saeed
چکیده

PURPOSE To directly compare the sensitivity of 64-section multidetector computed tomography (CT) with that of 1.5-T magnetic resonance (MR) imaging in the depiction and measurement of heterogeneous 7-8-week-old microinfarcts and the quantification of regional left ventricular (LV) function and perfusion in the territory of coronary intervention in a swine model. MATERIALS AND METHODS Approval was obtained from the institutional animal committee. An x-ray/MR system was used to catheterize the left anterior descending (LAD) coronary artery with x-ray guidance and to delineate the perfusion territory. The vessel was selectively microembolized in six pigs with small-diameter embolic material (40-120 microm, 250000 count). At 7-8 weeks after microembolization, multidetector CT and MR imaging were used to assess LV function, first-pass perfusion, and delayed contrast enhancement in remote myocardium and microinfarct scars. Histochemical staining with triphenyltetrazolium chloride (TTC) was used to confirm and quantify heterogeneous microinfarct scars. The two-tailed Wilcoxon signed rank test was used to detect differences between modalities and myocardial regions. RESULTS The LAD territory was 32.4% +/- 3.8(stadard error of the mean) of the LV mass. Multidetector CT and MR imaging have similar sensitivity in the detection of regional and global LV dysfunction and extent of microinfarct. The mean LV end-diastolic volume, end-systolic volume, and ejection fraction were 93 mL +/- 8, 46 mL +/- 4, and 50% +/- 3, respectively, on multidetector CT images and 92 mL +/- 8, 48 mL +/- 5, and 48% +/- 3, respectively, on MR images (P > or = .05). The extent of heterogeneous microinfarct was not significantly different between multidetector CT (6.3% +/- 0.8 of the LV mass), MR imaging (6.6% +/- 0.5 of the LV mass), and TTC staining (7.0% +/- 0.6 of the LV mass). First-pass multidetector CT and MR imaging demonstrated significant regional differences (P < .05) in time to peak between the heterogeneous microinfarct and remote myocardium (17.0 seconds +/- 0.3 and 12.4 seconds +/- 0.6, respectively, for multidetector CT and 17.2 seconds +/- 0.8 and 12.5 seconds +/- 1.0, respectively, for MR imaging). CONCLUSION Modern multidetector CT and MR imaging are sensitive modalities with which to depict heterogeneous microinfarcts and determine regional LV dysfunction and decreased perfusion in the territory of intervention. (c) RSNA, 2010.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the volume of coronary microemboli needed for reproducible visualization of microinfarcts on contrast enhanced MDCT and MRI

Methods Under X-ray guidance, a 3F catheter was placed selectively in LAD coronary artery of pigs (n=18). The animals received either 16mm or 32mm volumes of 40120μm Embosphere, microemboli (Biosphere Med, Rockland, MA) were selectively delivered in the LAD coronary artery to produce microinfarcts. The microemboli used were in the same size as those that pass through the pores of distal filtrat...

متن کامل

Coronary Microembolization with Normal Epicardial Coronary Arteries and No Visible Infarcts on Nitrobluetetrazolium Chloride-Stained Specimens: Evaluation with Cardiac Magnetic Resonance Imaging in a Swine Model

OBJECTIVE To assess magnetic resonance imaging (MRI) features of coronary microembolization in a swine model induced by small-sized microemboli, which may cause microinfarcts invisible to the naked eye. MATERIALS AND METHODS Eleven pigs underwent intracoronary injection of small-sized microspheres (42 µm) and catheter coronary angiography was obtained before and after microembolization. Cardi...

متن کامل

Hybrid SPECT/CT Imaging in the Evaluation of Coronary Stenosis: Role in Diabetic Patients

Purpose. Our purpose was to combine the results of the MDCT (multidetector computed tomography) morphological data and the SPECT (single-photon emission computed tomography) data using hybrid imaging to overcome the limits of the MDCT in the evaluation of coronary stenosis in diabetic patients with large amount of calcium in the coronary arteries. Method and Materials. 120 diabetic patients und...

متن کامل

Sinonasal Anatomical Variations: A Multidetector Computed Tomographic Study

Background and Aim: The paranasal sinuses are known for their complex anatomy and significant difference in size and shape. This study aimed to determine the prevalence of anatomical variations of the paranasal sinuses in computed tomography (CT). Materials and Methods: In this cross-sectional study, patients over 18 years of age, who had undergone CT imaging in a private clinic, were screened...

متن کامل

Evaluation of Reperfused Myocardial Infarction by Low-Dose Multidetector Computed Tomography Using Prospective Electrocardiography (ECG)-Triggering: Comparison with Magnetic Resonance Imaging

PURPOSE To evaluate the potential of prospective electrocardiography (ECG)- gated 64-slice multidetector computed tomography (MDCT) for evaluation of myocardial enhancement, infarct size, and stent patency after percutaneous coronary intervention (PCI) with stenting in patients with myocardial infarction. MATERIALS AND METHODS Seventeen patients who were admitted with acute myocardial infarct...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 254 3  شماره 

صفحات  -

تاریخ انتشار 2010