Importance of blood glucose meter and carbohydrate estimation accuracy.

نویسندگان

  • Naunihal S Virdi
  • John J Mahoney
چکیده

BACKGROUND The clinical significance of blood glucose meter (BGM) error in the presence of increasing carbohydrate errors in diabetes patients who use both the BGM result and the carbohydrate estimation to dose insulin is unknown. METHODS This Monte Carlo simulation modeled diabetes patients who calculate insulin dosages based on BGM results and carbohydrate estimations. It evaluated the likelihood of on-target insulin dosing and clinically significant insulin dose errors based on data from five BGMs with different levels of performance (expressed as bias and imprecision [coefficient of variation (%CV)]) and increasing levels of carbohydrate estimation errors. The study was performed across three separate preprandial glucose (PPG) ranges (90-150, 150-270, and 270-450 mg/dl). RESULTS When carbohydrate estimation is accurate (%CV = 0%), the likelihood for on-target insulin doses ranged 50.1-98.5%. The likelihood depended on BGM performance and PPG range. In the presence of carbohydrate estimation errors (%CV = 5-20%), the likelihood of on-target insulin dosages markedly decreased (range, 27.2-80.1%) for all BGMs, the likelihood of insulin underdosing (range, 0-12.8%) and overdosing (range, 0-32.3%) increased, and the influence of BGM error on insulin dosing accuracy was blunted. Even in the presence of carbohydrate error, the BGM with the best performance (bias 1.35% and %CV = 4.84) had the highest probability for on-target insulin dosages. CONCLUSIONS Both BGM and carbohydrate estimation error contribute to insulin dosing inaccuracies. The BGM with the best performance was associated with the most on-target insulin dosages.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Oral Carbohydrate Solutions on the Performance of Swimmers

It is well established that carbohydrate solutions can improve the performance in prolonged exercise. The aim of this study was to compare the impact of sugar and glucose solutions on exercise performance of swimmers. Twelve male teenager elite Iranian swimmers aged 12-17 years from Waterpolo Team of Ahvaz Oil Industry participated in a double-blind cross-over trial. They consumed three oral 6%...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Comment on “System Accuracy Evaluation of the GlucoRx Nexus Voice TD-4280 Blood Glucose Monitoring System”

Use of blood glucose (BG) meters in the self-monitoring of blood glucose (SMBG) significantly lowers the risk of diabetic complications. With several BG meters now commercially available, the International Organization for Standardization (ISO) ensures that each BG meter conforms to a set degree of accuracy. Although adherence to ISO guidelines is a prerequisite for commercialization in Europe,...

متن کامل

Evaluation of an Electrochemical Point‐of‐Care Meter for Measuring Glucose Concentration in Blood from Periparturient Dairy Cattle

BACKGROUND The Precision Xtra(®) meter is a promising low cost electrochemical point-of-care unit for measuring blood glucose concentration ([gluc]) in cattle blood. The meter uses an algorithm that assumes the intra-erythrocyte [gluc] equals the plasma [gluc] on a molal basis, and that the hematocrit is similar in humans and cattle. OBJECTIVES The primary objective was to determine the accur...

متن کامل

Accuracy of Capillary and Arterial Whole Blood Glucose Measurements Using a Glucose Meter in Patients under General Anesthesia in the Operating Room.

BACKGROUND The aim of this study was to evaluate the use of a glucose meter with surgical patients under general anesthesia in the operating room. METHODS Glucose measurements were performed intraoperatively on 368 paired capillary and arterial whole blood samples using a Nova StatStrip (Nova Biomedical, USA) glucose meter and compared with 368 reference arterial whole blood glucose measureme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2012