Laboratory Evaluation of the Influence of Decentration and Pupil Size on the Optical Performance of a Monofocal, Bifocal, and Trifocal Intraocular Lens.
PURPOSE To assess the influence of decentration and aperture size on the optical quality of different intraocular lenses (IOLs) of the same material, body design, and refractive power using standardized optical bench testing. METHODS Using an optical bench set-up, an aspheric monofocal (CT ASPHINA 409M; Carl Zeiss Meditec, Jena, Germany), an aspheric diffractive bifocal (AT LISA 809M; Carl Ze...
متن کامل[Contact lenses and intraocular lens power calculation: refractive surprise using the IOLMaster non-contact biometric method].
Dear Sir, This letter is to alert about the danger of carrying out biometric calculations for the intraocular lens without being aware that the patient may be using a contact lens. This warning is valid even when the highest precision research technology is being utilised. At present, errors in the calculation of the intraocular lens (IOL) are the most frequent cause of lens exchanges as well a...
متن کاملLight microscopy and scanning electron microscopy analysis of rigid curved interface femtosecond laser-assisted and manual anterior capsulotomy.
PURPOSE To study the microanatomic edge structures of anterior lens capsule specimens derived from manual and femtosecond laser-assisted capsulotomies. SETTING Department of Ophthalmology, Goethe-University, Frankfurt, Germany. DESIGN Experimental study. METHODS Of 60 eyes with lens removal and intraocular lens implantation, 30 received a manual capsulotomy and 30 received a femtosecond l...
متن کاملToric intraocular lenses for correction of astigmatism in keratoconus and after corneal surgery
PURPOSE To describe the results of cataract extraction with toric intraocular lens (IOL) implantation in patients with preexisting astigmatism from three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery). METHODS Cataract patients with topographically stable, fairly regular (although sometimes very high) corneal astigmatism underwent phacoemulsification with implan...
متن کاملAcute clouding of trifocal lens during implantation: a case report
BACKGROUND Intraoperative IOLs clouding of several kinds of hydrophilic acrylic intraocular lenses (IOLs) have been reported due to temperature changes. This phenomenon reported previously occurred in cold countries and during the winter months. However, no clinical case was reported about trifocal IOL opacification during operation. We report a case in which acute opacification of the optical ...