Repeatability and contact stress gradient detection of sealed pressure-sensitive film when used in a physiological joint model.

نویسندگان

  • G A Matricali
  • L Labey
  • W Bartels
  • G Dereymaeker
  • F P Luyten
  • J Vander Sloten
چکیده

Sealed pressure-sensitive film is frequently used to record contact characteristics in physiological joints. However, the effect on the pressure-recording characteristics of sealing the film when used in these circumstances has never been studied. This study compares the coefficient of variation, the standardized coefficient of variation, the tangent and secant contact stress gradients, and the actual pressures between unsealed and sealed Fuji film, in a simplified physiological joint model with a full-thickness surface defect. Unsealed film and sealed film were loaded through a range of nominal loads and the resulting stains were analysed by use of custom-made macros for the ImageJ image-processing program. The coefficient of variation did not exceed 5.7 per cent (sealed film), and the standardized coefficient of variation did not exceed 1.8 per cent (unsealed and sealed film). Contact stress gradients did not differ significantly. The recorded pressure at the level of surface defects was always about 0.2 MPa higher in the case of sealed film, and therefore predictable. It is concluded that sealing the film will not change the pressure-recording characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Proposed new signal for real-time stress monitoring: Combination of physiological measures

Human stress is a physiological tension that appears when a person responds to mental, emotional, or physical chal-lenges. Detecting human stress and developing methods to manage it, has become an important issue nowadays. Au-tomatic stress detection through physiological signals may be a useful method for solving this problem. In most of the earlier studies, long-term time window was considere...

متن کامل

A new sensor for measurement of dynamic contact stress in the hip.

Various techniques exist for quantifying articular contact stress distributions, an important class of measurements in the field of orthopaedic biomechanics. In situations where the need for dynamic recording has been paramount, the approach of preference has involved thin-sheet multiplexed grid-array transducers. To date, these sensors have been used to study contact stresses in the knee, shou...

متن کامل

I-19: Surrogate Egg Shell Culture for The Analysis of Avian Stem Cell Fate

Background: The chick embryo is a classical model to study embryonic development. However, most researchers have not studied the effect of embryonic manipulation on chick hatchability. To determine the effect of egg orientation and type of sealing film on the hatchability of cultured embryos, and to determine the fate of adulte stem cells injected into the blastoderm. Materials and Methods: Win...

متن کامل

Contact area and pressure distribution in the feline patellofemoral joint under physiologically meaningful loading conditions.

The purpose of this study was to determine contact area and mean and peak pressures in the healthy feline patellofemoral joint over the complete range of possible applied force. Furthermore, we wanted to improve upon the repeatability of previous measurements while maximizing the physiological relevance of the results obtained. The patellae and femora were secured in a loading frame approximati...

متن کامل

Impact of Blood Vessel Wall Flexibility on the Temperature and Concentration Dispersion

The analysis of solute and thermal dispersion in pulsatile flow through the stenotic tapered blood vessel is presented. The present problem is an extension of the work done by Ramana et al. who considered the time-invariant arterial wall. In the present model, the flexible nature of the arterial wall through the obstruction (called stenosis) is considered and it is achieved with the he...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 222 7  شماره 

صفحات  -

تاریخ انتشار 2008