[Visual performance in myopic correction with spectacles and soft contact lenses].

نویسندگان

  • Breno Barth
  • Mílton Ruiz Alves
  • Newton Kara-José
چکیده

PURPOSE To evaluate the visual performance by high contrast visual acuity, contrast sensitivity and wavefront in myopic patients with or without astigmatism corrected with spectacles and with three different soft contact lenses [Acuvue 2 (Vistacon J&J Vision Care Inc., USA), Biomedics 55 (Ocular Science, USA), and Focus 1-2 week (Ciba Vision Corporation, USA)]. METHODS An interventional prospective clinical trial studied a sample of 40 myopic patients (-1.00 to -4.50 sph, with or without astigmatism up to -0.75 cyl). Each patient had one eye randomized to visual performance evaluation. RESULTS The Zywave aberrometer detected a over refraction and significant difference between Acuvue 2 and Biomedics 55 regarding spheric refractive components and spheric equivalent. Both soft contact lenses showed hypercorrection as compared to Focus 1-2 week. Visual performance was not significantly different with spectacles and the three soft contact lenses in visual acuity and contrast sensitivity measurements. The wavefront analysis detected a significant difference in a third order aberration with and without soft contact lenses, with better visual performance with Acuvue 2 and Biomedics 55. CONCLUSION In visual performance evaluation with spectacles and soft contact lenses the wavefront analysis was a more sensible measurement of visual function when compared to high contrast visual acuity and contrast sensitivity. The evaluation model of visual performance with wavefront analysis developed in this investigation may be useful for further similar studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of methods of myopia correction on visual acuity, contrast sensitivity, and depth of focus.

PURPOSE To psychophysically measure spherical and irregular aberrations in patients with various types of myopia correction. SETTING Laboratory of Experimental Ophthalmology, University of Groningen, Groningen, The Netherlands. METHODS Three groups of patients with low myopia correction (spectacles, soft contact lens, and Intacs) and 4 groups with high myopia correction (spectacles, rigid c...

متن کامل

The level of improvement of visual acuity in high corneal astigmatism with rigid gas permeable contact lenses.

The aim of this study was to calculate the level of improvement of visual acuity comparing the best corrected visual acuity (VA) achieved with spectacles with the best corrected VA achieved with rigid gas permeable (RGP) contact lenses in patients with high, simple or compound corneal astigmatism (myopic, hypermetropic and mixed). The investigation of patients included auto-kerato-refractometry...

متن کامل

Myopia control in children through refractive therapy gas permeable contact lenses: is it for real?

PURPOSE To compare the safety and efficacy of orthokeratology as a nonsurgical treatment for myopia in children with alternate methods, such as soft contact lenses, rigid gas permeable lenses, and spectacles, throughout multiple studies. DESIGN Perspective with literature review. METHODS Analysis of recent studies to determine the safety and effectiveness of orthokeratology versus soft cont...

متن کامل

Contact lenses as the best conservative treatment of newly diagnosed keratoconus--epidemiological retrospective study.

Keratoconus is a progressive, non-inflammatory corneal ectasia characterized by thinning and weakening of the corneal stroma which results in its' protrusion. The onset is during puberty and progresses until the fourth decade of life. In earlier stages, good visual acuity can be provided with spectacles. With progression, contact lenses are considered to be a better therapy. Aim of this study w...

متن کامل

Peripheral myopization and visual performance with experimental rigid gas permeable and soft contact lens design.

PURPOSE To evaluate the performance of two experimental contact lenses (CL) designed to induce relative peripheral myopic defocus in myopic eyes. METHODS Ten right eyes of 10 subjects were fitted with three different CL: a soft experimental lens (ExpSCL), a rigid gas permeable experimental lens (ExpRGP) and a standard RGP lens made of the same material (StdRGP). Central and peripheral refract...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 71 1  شماره 

صفحات  -

تاریخ انتشار 2008