Clinical Experience with a Hybrid Procedure Using the Adherent Clot Catheter for Salvage of Thrombosed Hemodialysis Access: A Comparison with the Standard Fogarty Balloon Catheter
نویسندگان
چکیده
PURPOSE This study aimed to compare the efficacy of two different catheters in hybrid surgery for salvage of thrombosed hemodialysis accesses. MATERIALS AND METHODS The hybrid salvage procedure (surgical thrombectomy followed by endovascular angioplasty) of the thrombosed hemodialysis access, was performed using adherent clot (AC) catheter in 140 cases and Fogarty balloon catheter in 68 cases. Procedure-related outcomes such as the clot removal status, clinical success, complications, and primary patency rates were analyzed retrospectively. RESULTS The proportion of cases with good clot removal scores in the AC catheter and Fogarty balloon catheter groups was 77.9% and 91.2%, respectively (P=0.018). Clinical success was achieved in 90.7% of the cases in the AC catheter group and in 98.5% of the cases in the balloon catheter group (P=0.035). The mean patency rates of the two groups were 50.7% and 63.2% at 3 months, 40.7% and 47.1% at 6 months, and 17.9% and 19.1% at 12 months. The complication rates (12.1% and 5.9%) and primary patency rates between the two catheters were not statistically different (P=0.328). On the analysis of the patency rate on access type of autologous (P=0.169) and prothetic graft (P=0.423), there was no significant difference between the two catheter groups. CONCLUSION In terms of clot removal and clinical success, the AC catheter did not demonstrate better outcomes than the Fogarty balloon catheter. However, primary patency was not related to the type of catheter. Adherent clot catheter can be a useful alternative to Fogarty balloon catheter for thrombosed hemodialysis access.
منابع مشابه
The Impact of Intraluminal Vancomycin Adminstration on Prevention of Hemodialysis CatheterRelated Infections
Introduction: Percutaneously inserted double-lumen central venous hemodialysis catheters provide the nephrologist with an excellent temporary access for an immediate hemodialysis treatment and preserve the peripheral veins for the future creation of a permanent arteriovenous vascular access. Unfortunately catheterrelated infections are usually common. In this study, the impact of intra luminal ...
متن کاملIntraoperative Balloon Angioplasty Using Fogarty Artertial Embolectomy Balloon Catheter for Creation of Arteriovenous Fistula for Hemodialysis: Single Center Experience
BACKGROUND The purpose of this study was to evaluate the use of a Fogarty arterial embolectomy catheter (Fogarty catheter) in intraoperative balloon angioplasty of the cephalic vein, in order to determine its effect on the patency of arteriovenous fistulas (AVFs) created for hemodialysis access. METHODS A total of 156 patients who underwent creation of an AVF were divided into two groups, bas...
متن کاملSkin fold technique for central venous catheter fixation; Comparison with conventional method for postopration infections
Background: Central Venous Catheters (CVCs) are used not only as a tool to access to central venous system, but also for hemodynamic monitoring, parenteral nutrition, chemotherapy and hemodialysis. The use of CVCs is associated with some complications notably infections that are troublesome both to patient and physician. We conducted this study to examine catheter fixation with skin fold techni...
متن کاملPercutaneous salvage of thrombosed immature arteriovenous fistulas.
Thrombosed immature fistulas have historically been considered unsalvageable. However, advances in procedure and balloon catheter technologies have expanded the scope of endovascular treatments. This study investigates the efficacy, functionality, and cost associated with the use of percutaneous techniques for the salvage of thrombosed immature fistulas. Over a 2-year period and from a populati...
متن کاملFogarty balloon application technique in dislodging residual thrombus on the single sheath entry point at the apex of thrombosed loop grafts.
PURPOSE We aimed to evaluate the effectiveness of the Fogarty balloon application in dislodging residual thrombus at the sheath entry point in a graft by using single apex puncture to declot thrombosed hemodialysis loop grafts. MATERIALS AND METHODS The apex puncture technique was used in 520 cases to declot 376 hemodialysis loop grafts (male/female, 150/226; mean age, 58 years). The Fogarty ...
متن کامل