Removal of P-cresol sulfate by hemodialysis.

نویسندگان

  • Andres W Martinez
  • Natalie S Recht
  • Thomas H Hostetter
  • Timothy W Meyer
چکیده

Protein-bound solutes are poorly cleared by dialysis. Among the most extensively studied of these solutes is p-cresol, which has been shown to be toxic in vitro. This study examined the form in which p-cresol circulates and quantified its removal by hemodialysis. HPLC analysis of plasma from hemodialysis patients contained a peak whose mobility corresponded to synthetic p-cresol sulfate (PCS) but no detectable unconjugated p-cresol. Treatment with sulfatase resulted in recovery of this peak as p-cresol, confirming its identity. Subsequent studies compared the removal of PCS and another protein-bound solute, indican, to the removal of urea during clinical hemodialysis treatments. PCS and indican were 94 +/- 1% and 93 +/- 2% bound to plasma protein, respectively. Protein-binding caused a predictable decrease in measured dialytic clearance, which averaged 20 +/- 4 ml/min for PCS and 25 +/- 5 ml/min for indican as compared with 260 +/- 20 ml/min for urea. Volumes of distribution for the protein-bound solutes were greater than the plasma volume, averaging 15 +/- 7 L for PCS and 14 +/- 3 L for indican as compared with 37 +/- 7 for urea. Solute reduction ratios were 20 +/- 9% for PCS, 30 +/- 7% for indican, and 69 +/- 5% for urea. We conclude that p-cresol circulates in the form of its sulfate conjugate, PCS. PCS is poorly removed by hemodialysis because its clearance is limited by protein binding and the ratio of its volume of distribution to its clearance is high.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contribution of residual function to removal of protein-bound solutes in hemodialysis.

BACKGROUND AND OBJECTIVES This study evaluated the contribution of residual function to the removal of solutes for which protein binding limits clearance by hemdialysis. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Solute concentrations were measured in 25 hemodialysis patients with residual urea clearances ranging from 0.1 to 6.2 ml/min per 1.73 m2. Mathematical modeling assessed the effect...

متن کامل

Effect of increasing dietary fiber on plasma levels of colon-derived solutes in hemodialysis patients.

BACKGROUND AND OBJECTIVES Numerous uremic solutes are derived from the action of colon microbes. Two such solutes, indoxyl sulfate and p-cresol sulfate, have been associated with adverse outcomes in renal failure. This study tested whether increasing dietary fiber in the form of resistant starch would lower the plasma levels of these solutes in patients on hemodialysis. DESIGN, SETTING, PARTI...

متن کامل

An Investigation of p-Nitro Cresol Removal from Aqueous Environment by Fenton Process in a Batch Reactor

Background & Aims of the Study: One of the most carcinogenic and toxic pollutants is p-Nitro Cresol. In this study, the degradation and mineralization of p-Nitro Cresol in aqueous solution were investigated by Fenton process in a batch reactor. Materials & Methods: This study is an experimental research on a laboratory scale. The study executed on synthetic wastewater hav...

متن کامل

Retained organic solutes, patient characteristics and all-cause and cardiovascular mortality in hemodialysis: results from the retained organic solutes and clinical outcomes (ROSCO) investigators

BACKGROUND Multiple solutes are retained in uremia, but it is currently unclear which solutes are toxic. Small studies suggest that protein-bound solutes, such as p-cresol sulfate and indoxyl sulfate and intracellular solutes, such as methylamine (MMA) and dimethylamine (DMA), may be toxic. Our objective was to test whether elevated levels of these solutes were associated with mortality. METH...

متن کامل

Removal of the protein-bound solutes indican and p-cresol sulfate by peritoneal dialysis.

BACKGROUND AND OBJECTIVES Protein-bound solutes are poorly cleared by peritoneal dialysis. We examined the hypothesis that plasma concentrations of bound solutes would therefore rise as residual renal function is lost. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS Clearances of urea indican and p-cresol sulfate were measured in peritoneal dialysis patients with and without residual function. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Nephrology : JASN

دوره 16 11  شماره 

صفحات  -

تاریخ انتشار 2005