Boost Converter for Power Factor Correction of DC Motor Drive

نویسنده

  • K.VENKATESWARA RAO
چکیده

With the increasing demand for power from the ac line and more stringent limits for power quality, power factor correction has gained great attention in recent years. A variety of circuit topologies and control methods have been developed for the PFC application. While the discontinuous conduction mode (DCM) converters such as boost and flyback converters are well suited for low power applications, continuous conduction mode (CCM) boost converters with average current mode, peak current mode or hysteresis control are commonly chosen for many medium and high power applications. Harmonic pollution and low power factor in power systems caused by power converters have been of great concern. To overcome these problems several converter topologies using advanced semiconductor devices and control schemes have been proposed. This investigation is to identify a low cost, small size, efficient and reliable ac to dc converter to meet the input performance index of UPS. The performance of single phase and three phase ac to dc converter along with various control techniques are studied and compared. This paper presents a novel ac/dc converter based on a quasi-active power factor correction (PFC) scheme. In the proposed circuit, the power factor is improved by using boost dc to dc converter. It eliminates the use of active switch and control circuit for PFC, which results in lower cost and higher efficiency. A Matlab/Simulink based model is developed and simulation results are presented. Finally a DC motor load is applied and simulation results are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modified Bi-directional AC/DC Power Converter with Power Factor Correction

Most existing power  converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...

متن کامل

Buck-Boost Converter for BLDC Motor Drive to Improve Power Factor

This paper presents an influence issue improved by victimisation buck-boost convertor for BLDC motor drive as a value effective answer for low power applications. AN approach of speed management of BLDC motor by dominant the DC link voltage of VSI (Voltage supply Inverter) is employed. This facilitates the operation of VSI at fundamental change by victimisation the electronic commutation of BLD...

متن کامل

A Single Sensor, Single Switch Integrated PFC Buck- Boost Buck Converter Fed BLDC Motor Drive

This paper presents an integrated power factor correction (PFC) buck-boost buck converter based voltage source inverter (VSI) fed brushless DC motor (BLDC) drive using a single voltage sensor. The speed is controlled by controlling the DC bus voltage of the VSI. An electronic commutation of the BLDC motor is used which utilizes a fundamental frequency switching (FFS) of VSI which in-turn offers...

متن کامل

Power Factor Correction Using Step-Up Chopper Fed to a DC Motor Drive

With the expanding interest for power from the ac line and more stringent cutoff points for power quality, power factor correction is extraordinary consideration as of late. An assortment of circuit topologies and control strategies has been created for the PFC application. While the discontinuous conduction mode (DCM) converters for example, boost and fly back converters are appropriate for lo...

متن کامل

Modeling and Simulation of a Novel Switched Reluctance Motor Drive System with Power Factor Improvement

This study presents a novel Switched Reluctance Motor (SRM) drive system with power factor improvement. Recently, many of the converters with variable speed drives have no input power factor correction circuits. This results in harmonic pollution of the utility supply, which should be avoided. The effect of power factor variation in terms of harmonic content is also analyzed in this study. The ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012