New Drug-Eluting Stents

نویسندگان

  • Young Joon Hong
  • Myung Ho Jeong
چکیده

The introduction of drug-eluting stents (DES) has rapidly and profoundly affected the field of interventional cardiology, and DESs are now used in a majority of intracoronary stenting procedures. As a result of the innumerable “trial-and-error” endeavors, DESs have emerged as a potential solution for solving the problem of restenosis. DESs are coated stents capable of releasing single or multiple bioactive agents into the bloodstream and the surrounding tissues. The efficacy and safety of DESs might differ depending on the pharmacologic agents and stent delivery systems that are used. Recent research has focused on the various constituents of DESs, including the stent backbone, the materials used as drug-delivery vehicles, and the physicochemical properties of the pharmacotherapeutic agents themselves. Stent-induced mechanical arterial injury and a foreign body response to the prosthesis incite acute and chronic inflammation in the vessel wall, along with the elaboration of cytokines and growth factors that induce multiple signaling pathways to activate smooth muscle cell migration and proliferation. Utilization of antiproliferative agents delivered locally via the drug-eluting stents has dramatically reduced the stent restenosis rate. The polymer-regulated delivery of both paclitaxel and sirolimus at the site of arterial injury has been shown to reduce the clinical and angiographic restenosis rates after stent implantation in de novo coronary lesion. Other DESs have yielded somewhat less brilliant results or even true failures, while a number of new drugs and new stent platforms are now under clinical or preclinical evaluation. In this review, we describe the main clinical trials on DESs and the most recent information that has been derived from observational studies and registries. Moreover, the preliminary results on the new DESs are also summarized. (Korean Circulation J 2005;35:197-205)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and Efficacy of New Sirolimus-eluting Stent Models in a Preclinical Study.

INTRODUCTION AND OBJECTIVES Initial preclinical studies are required during the process of improving polymers, platforms, and drug-eluting systems for new coronary stent designs. Our objective was to analyze the efficacy and safety of new drug-eluting stent models compared with a conventional stent and commercialized drug-eluting stents in an experimental model with healthy porcine coronary art...

متن کامل

A three-dimensional mathematical model for drug delivery from drug-eluting stents

Current drug-eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug release, more research on the <span style="font-size: 12pt; color: #000000; font-style: normal; ...

متن کامل

Immunosuppressive therapy and tolerance of organ allografts.

Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-23. Stone GW, Ellis SG, Cox DA, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004;350:221-31. Pfisterer M, Brunner-La Rocca HP, Buser PT, et al. Late clinical events after ...

متن کامل

Drug-eluting versus bare-metal stents in large coronary arteries.

BACKGROUND Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether this increase in risk was also seen with second-generation drug-eluting stents. METHOD...

متن کامل

Long-term safety and efficacy of drug-eluting versus bare-metal stents in Sweden.

BACKGROUND The long-term safety and efficacy of drug-eluting coronary stents have been questioned. METHODS We evaluated 47,967 patients in Sweden who received a coronary stent and were entered into the Swedish Coronary Angiography and Angioplasty Registry between 2003 and 2006 and for whom complete follow-up data were available for 1 to 5 years (mean, 2.7). In the primary analysis, we compare...

متن کامل

A comparison of bare-metal and drug-eluting stents for off-label indications.

BACKGROUND Recent reports suggest that off-label use of drug-eluting stents is associated with an increased incidence of adverse events. Whether the use of bare-metal stents would yield different results is unknown. METHODS We analyzed data from 6551 patients in the National Heart, Lung, and Blood Institute Dynamic Registry according to whether they were treated with drug-eluting stents or ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006