Laser intrastromal keratomileusis for high myopia and myopic astigmatism.

نویسندگان

  • P I Condon
  • M Mulhern
  • T Fulcher
  • A Foley-Nolan
  • M O'Keefe
چکیده

BACKGROUND Laser intrastromal keratomileusis (LASIK) is an evolving technique which enables high degrees of myopia (> 8.0 dioptres) and myopic astigmatism to be corrected. This paper describes initial experience with this procedure. It also details the methodology, the results, the problems encountered, and discusses retreatment procedures. METHODS 51 eyes (48 primary cases and three retreatments) underwent LASIK for simple myopia or compound myopic astigmatism. After the keratotomy was fashioned with a Chiron corneal shaper, the ablation was performed with either a Summit or Meditec excimer laser. The actual preoperative astigmatism ranged from -0.5 D to -6.0 D (in the astigmatic myopic LASIK (AML) series), while the range of preoperative myopia in the combined myopic LASIK (ML) and AML series was -8.0 D to -37.0 D. Of the ML cases, group 1 (-8.0 to 15.0 D (dioptres)), group 2 (> -15.0 to -20.0 D), and group 3 (> -20.0 D) had mean preoperative myopia values (spherical equivalent) of -11.26 D, -16.84 D and -27.78 D. The same groupings (1, 2, and 3) for the AML cases had respective values of -9.702, -17.4, and -23.08. In the AML series the mean preoperative astigmatism was -2.109 D. Follow up ranged from 8 to 27 months (mean 15.8 months). Six of the cases required retreatment. RESULTS There was a reduction in best corrected visual acuity (BCVA) (of 1 Snellen line) in seven of the primary cases (14.5%) (three in the ML group and four in the AML group), and in one of the retreatment cases. The BCVA improved in 28 cases (58%) in the primary treatment group. The mean correction attempted (spherical equivalent) for the ML groups 1, 2, and 3 was 10.51 D, -14.5 D, and -27.78 D, versus a mean correction achieved of -9.445 D, -15.625 D, and -21.571 D. Similarly, for the AML groups, attempted correction values were -9.702 D, -17.4 D, and -23.08 D, while the values achieved were -6.95 D, -51.425 D, and -15.708 D. Regression was minimal and stabilisation of the refractive result was achieved in all groups, except group 3 of the ML series, by the 3 month examination period. The mean postoperative astigmatism in the AML series was -0.531 D. Vector analysis of the AML series showed that the mean surgically induced astigmatism was +0.93 D. The most common complication encountered was undercorrection, which occurred in 35 cases-23 cases in the ML group and 12 cases in the AML series. Twenty eight per cent of the ML cases, and 25% of the AML cases were within plus or minus 1.5 D of the attempted refraction. CONCLUSION For the correction of high myopia and myopic astigmatism, LASIK results in less postoperative pain and relatively little subepithelial haze compared with high myopic photorefractive keratectomy. Furthermore, a stable refraction and reasonably predictable outcome occurs much earlier. High myopia up to -37.0 D can be corrected, albeit with some limitations at the extremes of myopia-in terms of the amount of myopia correctable; this represents a limitation of the technique. Retreatment is a technically straightforward and effective way to treat undercorrection. Undercorrection, the main complication seen in our series, should become less common when the ablation algorithms are further refined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Refractive lenticule extraction (ReLEx) through a small incision (SMILE) for correction of myopia and myopic astigmatism: current perspectives

Small-incision lenticule extraction (SMILE) is an alternative to laser-assisted in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) for the correction of myopia and myopic astigmatism. SMILE can be performed for the treatment of myopia ≤-12 D and astigmatism ≤5 D. The technology is currently only available in the VisuMax femtosecond laser platform. It offers several advantages ...

متن کامل

LASIK for Spherical Refractive Myopia: Effect of Topographic Astigmatism (Ocular Residual Astigmatism, ORA) on Refractive Outcome

PURPOSE In eyes with a preoperative plano refractive cylinder, it would appear that there is no rationale for astigmatic treatment. The aim of this retrospective, cross-sectional data analysis was to determine the amount of topographic astigmatism in refractive plano eyes that results in reduced efficacy after myopic laser in situ keratomileusis (LASIK). METHODS This study included 267 eyes f...

متن کامل

Femtosecond laser-assisted sub-Bowman keratomileusis versus laser-assisted subepithelial keratomileusis to correct myopic astigmatism

PURPOSE To compare femtosecond laser-assisted sub-Bowman keratomileusis (FSBK) versus laser-assisted subepithelial keratomileusis (LASEK) to correct moderate to high myopic astigmatism. METHODS Retrospective, nonrandomized, interventional, comparative case series. A total of eight hundred and fifty-two eyes with myopic astigmatism of -1.5 diopters (D) or higher were included in the study. We ...

متن کامل

Therapeutic alloplastic laser in situ keratomileusis for myopia.

BACKGROUND A new technique, therapeutic alloplastic laser in situ keratomileusis to correct high myopia, is introduced. METHODS Therapeutic alloplastic laser in situ keratomileusis consists of neutral homoplastic epikeratoplasty combined with superficial keratectomy performed with an excimer laser and/or a microkeratome. Indications for the technique are: myopia over 20 diopters (D), eyes wit...

متن کامل

Clinical outcomes of wavefront-guided laser in situ keratomileusis to treat moderate-to-high astigmatism

PURPOSE The purpose of this study was to evaluate the refractive and visual outcomes of wavefront-guided laser in situ keratomileusis (LASIK) in eyes with myopic astigmatism and cylindrical component ≥2.0 diopter (D). METHODS In this retrospective study, 611 eyes that underwent LASIK for simple or compound myopic astigmatism were analyzed. Preoperative refractive cylinder ranged from -2.00 D ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 81 3  شماره 

صفحات  -

تاریخ انتشار 1997