Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla.
نویسندگان
چکیده
In this work experimental and numerical studies of the MR signal were performed at frequencies ranging from 64 MHz to 485 MHz, utilizing three different MRI coils: a single-strut transverse electromagnetic (TEM)-based coil, a TEM resonator, and a high-pass birdcage coil. The experimental analyses were conducted using 1.5 and 8 Tesla whole-body systems and volume RF head coils. The simulation data were obtained utilizing an in-house-developed finite difference time domain (FDTD) model. Pertinent data from the numerical and experimental setups were compared, and a remarkable agreement between the two methods was found that clearly demonstrates the effectiveness of the FDTD method when it is applied rigorously. The numerical and experimental studies demonstrate the complexity of the electromagnetic (EM) fields and their role in the MR signal. These studies also reveal unique similarities and differences between the transmit and receive field distributions at various field strengths. Finally, for ultra high-field operations, it was demonstrated mathematically, numerically, and experimentally that highly asymmetric inhomogeneous images can be acquired even for linear excitation, symmetrical load geometries, and symmetrical load positioning within the coil.
منابع مشابه
Hole-Slotted Phased Array at 7 Tesla
Introduction The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Multi channel receiver arrays have been shown to increase the SNR and/or the speed (if combined with parallel imaging) in clinical and animal MRI studies [1]. Array coils for high fields are usually based on simple loops and are mostly used in rat imaging studies ...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملDesign and Fabrication of Helmholtz Coils to Study the Effects of Pulsed Electromagnetic Fields on the Healing Process in Periodontitis: Preliminary Animal Results
Background: Effects of electromagnetic fields on healing have been investigated for centuries. Substantial data indicates that exposure to electromagnetic field can lead to enhanced healing in both soft and hard tissues. Helmholtz coil is a device that generates pulsed electromagnetic fields. Objective: In this study, a pair of Helmholtz coils for enhancing thehealing process in periodontitis w...
متن کاملIn vivo multiple-mouse MRI at 7 Tesla.
We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost ar...
متن کاملApplication of an End-user Friendly Cryogenic Coil for in Vivo High Resolution Medical Image on 3t Whole Body Scanner a Novel Liquid Nitrogen Cryostat and Coil for High-resolution In-vivo Imaging on a 3 Tesla Whole Body Scanner
The design and operation of a receive-only liquid nitrogen (LN2) cooled coil and cryostat suitable for medical image on 3T whole body MR scanner is presented. The coil size, optimised for murine imaging, was determined by using electromagnetic (EM) simulations. This process is therefore easier and more cost-effective than building a range of coils. A non-magnetic cryostat suitable for small ani...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 54 3 شماره