Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla.

نویسندگان

  • Tamer S Ibrahim
  • Chad Mitchell
  • Petra Schmalbrock
  • Robert Lee
  • Donald W Chakeres
چکیده

In this work experimental and numerical studies of the MR signal were performed at frequencies ranging from 64 MHz to 485 MHz, utilizing three different MRI coils: a single-strut transverse electromagnetic (TEM)-based coil, a TEM resonator, and a high-pass birdcage coil. The experimental analyses were conducted using 1.5 and 8 Tesla whole-body systems and volume RF head coils. The simulation data were obtained utilizing an in-house-developed finite difference time domain (FDTD) model. Pertinent data from the numerical and experimental setups were compared, and a remarkable agreement between the two methods was found that clearly demonstrates the effectiveness of the FDTD method when it is applied rigorously. The numerical and experimental studies demonstrate the complexity of the electromagnetic (EM) fields and their role in the MR signal. These studies also reveal unique similarities and differences between the transmit and receive field distributions at various field strengths. Finally, for ultra high-field operations, it was demonstrated mathematically, numerically, and experimentally that highly asymmetric inhomogeneous images can be acquired even for linear excitation, symmetrical load geometries, and symmetrical load positioning within the coil.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hole-Slotted Phased Array at 7 Tesla

Introduction The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Multi channel receiver arrays have been shown to increase the SNR and/or the speed (if combined with parallel imaging) in clinical and animal MRI studies [1]. Array coils for high fields are usually based on simple loops and are mostly used in rat imaging studies ...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Design and Fabrication of Helmholtz Coils to Study the Effects of Pulsed Electromagnetic Fields on the Healing Process in Periodontitis: Preliminary Animal Results

Background: Effects of electromagnetic fields on healing have been investigated for centuries. Substantial data indicates that exposure to electromagnetic field can lead to enhanced healing in both soft and hard tissues. Helmholtz coil is a device that generates pulsed electromagnetic fields. Objective: In this study, a pair of Helmholtz coils for enhancing thehealing process in periodontitis w...

متن کامل

In vivo multiple-mouse MRI at 7 Tesla.

We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost ar...

متن کامل

Application of an End-user Friendly Cryogenic Coil for in Vivo High Resolution Medical Image on 3t Whole Body Scanner a Novel Liquid Nitrogen Cryostat and Coil for High-resolution In-vivo Imaging on a 3 Tesla Whole Body Scanner

The design and operation of a receive-only liquid nitrogen (LN2) cooled coil and cryostat suitable for medical image on 3T whole body MR scanner is presented. The coil size, optimised for murine imaging, was determined by using electromagnetic (EM) simulations. This process is therefore easier and more cost-effective than building a range of coils. A non-magnetic cryostat suitable for small ani...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2005