Development of a cone-shape phantom for multi-voxel MR spectroscopy.

نویسندگان

  • Dong-Cheol Woo
  • Bum-Soo Kim
  • So-Lyung Jung
  • Hyo-Jin Park
  • Hyang-Shuk Rhim
  • Geon-Ho Jahng
  • Bo-Young Choe
چکیده

The purpose of this study was to develop a cone-shape phantom for multi-voxel magnetic resonance spectroscopy (MRS) and to evaluate MR spectra using the cone-shape phantom we developed in this study. A cone-shape MRS phantom was developed with a combination of cone-shape vials. The cylindrical main body was made of acrylic resin and the cone-shape vials were fabricated from poly-ethylene cones. Each cone of the phantom was filled with various metabolite materials. 1.5T GE and 3T Philips systems were used for the single voxel spectroscopy (SVS) as well as for the multi-voxel spectroscopy (MVS). Identification and quantification of the metabolite materials in the cone-shape phantom were done by the SAGE post-program. The MR images and spectra of the cone-shape phantom were obtained from the assigned slice position. The high order shimming control provided enhanced resolution in the SVS and MVS. The area and amplitude were proportional to the metabolite volume in the voxel. The present study demonstrated that the cone-shape phantom was useful for the metabolite quantification. Thus, we propose that the cone-shape phantom can be used for the evaluation of quality control of the MR spectra obtained from SVS and MVS.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of contrast material on single-volume proton MR spectroscopy.

BACKGROUND AND PURPOSE Administration of contrast material before proton MR spectroscopy may allow more accurate placement of the volume of interest, particularly in tumors; yet, some data have suggested that contrast material may alter the results of MR spectroscopy. To determine the validity of this contention, we performed pre- and postcontrast MR spectroscopy in patients with brain tumors a...

متن کامل

Quantification of Fatty Acid Compositions Using MR-imaging and Spectroscopy at 3 T

Introduction Multi-echo imaging has previously been used for fat/water separation and fat quantification [1,2]. The same technique may potentially also be able to differentiate different fat types depending on the amount of unsaturated fatty acids. The fatty acid composition of adipose tissue is not only dependent on the diet, but may also be interesting in e.g. chronic inflammations [3]. Also,...

متن کامل

A CVH-based computational female pelvic phantom for radiation dosimetry simulation

Background: Accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. Materials and Methods: A computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed base...

متن کامل

Correlation of single photon emission CT with MR image data using fiduciary markers.

PURPOSE To describe our approach to mapping the functional information provided by single photon emission computed tomography (SPECT) onto the anatomic template provided by MR, and to determine both the number of markers required to achieve accuracy and the impact of voxel shape on accuracy. METHODS Point-to-point iterative minimization using externally fixed fiducial markers was involved and...

متن کامل

Conventional Voxel in Tomographic Reconstruction Based upon Plane-Integral Projections – Use It or Lose It?

Introduction: While the necessity of replacing voxels with blobs in conventional tomographic reconstruction based upon line-integrals is clear, it is not however well-investigated in plane- integral-based reconstruction. The problem is more challenging in convergent-plane projection reconstruction. In this work, we are aiming at utilizing blobs as alternative to voxels. <stron...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neuroscience methods

دوره 162 1-2  شماره 

صفحات  -

تاریخ انتشار 2007