Comparison of procedures for evaluating laboratory performance in external quality assessment schemes for lead in blood and aluminum in serum demonstrates the need for common quality specifications.
نویسندگان
چکیده
BACKGROUND The different scoring methods used by eight European External Quality Assessment Schemes (EQASs) for occupational and environmental laboratory medicine were compared to develop suitable quality specifications as a step toward harmonization. METHODS Real results for blood lead and serum aluminum assays, reported by participants in Italian and United Kingdom EQASs, were evaluated according to individual scheme scoring criteria. The same results were then used to produce z scores using scheme-based between-laboratory SDs as the estimate of variability to determine whether simple performance-derived quality specifications produced better agreement among schemes. RESULTS The schemes gave conflicting assessments of participants' performance, and participants judged to be successful by one scheme could be defined as performing inadequately by another. An approach proposed by Kenny et al. (Scand J Clin Lab Invest 1999;59:585), which uses clinical inputs to set targets for analytical imprecision, bias, and total error allowable, was then used to elaborate quality specifications. CONCLUSIONS We suggest that the CLIA '88 recommendations for blood lead (+/- 40 micro g/L or +/- 10% of the target concentration, whichever is the greater) could be used as a quality specification, although a revision to +/- 30 micro g/L or +/- 10% is recommended. For serum aluminum, a suitable quality specification of +/- 5 micro g/L or +/- 20% of the target concentration, whichever is the greater, is suggested. These specifications may be used to compare laboratory performance across schemes.
منابع مشابه
I-4: External Quality Assessment - A Necessity in The Andrology Laboratory
Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...
متن کاملQuality specifications for the determination of copper, zinc, and selenium in human serum or plasma: evaluation of an approach based on biological and analytical variation.
BACKGROUND Trace element external quality assessment schemes monitor laboratory performance and provide a stimulus for improvement in accuracy. However, monitoring of participant performance varies according to the scheme and can lead to conflicting conclusions. METHODS Quality specifications based on biological intra- and interindividual variability were calculated and compared to those curr...
متن کاملMethodological Review for Capacity and Punctuality Assessment Procedures
Climate change, congestion, safety, energy consumption and pollution are among the major issues that the European :::union::: and the wider world are facing nowadays. The European Commission is working towards the creation of a Single European Railway Area, encouraging a modal shift towards rail (mainly from road) in order to achieve a more competitive and sustainable European transport syst...
متن کاملA New Technique for Quality Assessment of Railway Ballast Materials
The influence of main quality tests on the overall quality of railway ballast materials is assessed in this study. The need to integrate all acceptance tests in a unified manner for precise evaluation of ballast quality is identified, and a technique of performing this is proposed. Using this approach, a new ballast quality index (BQI) is defined in which, the main acceptance tests including ab...
متن کاملComparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 48 11 شماره
صفحات -
تاریخ انتشار 2002