Measurement of plasma renin activity with use of HPLC-electrospray-tandem mass spectrometry.

نویسندگان

  • V F Fredline
  • E M Kovacs
  • P J Taylor
  • A G Johnson
چکیده

BACKGROUND The measurement of renin activity is complicated by difficulties in the quantification of angiotensin 1 (Ang1), the product of the renin-catalyzed reaction. We report an HPLC-electrospray-tandem mass spectrometry (HPLC-ESI-MS/MS) method for the quantification of Ang1 as a measure of plasma renin activity (PRA). METHODS After incubation (37 degrees C for 3 or 18 h), samples were prepared using C18 solid-phase extraction. [Val]5Ang1 was used as the internal standard (IS). Chromatography was performed on a C18 column, using 200 mL/L ammonium acetate buffer-800 mL/L methanol as the mobile phase. The flow rate was 150 microL/min, with a chromatographic run time of 5 min/sample. Mass spectrometric detection was in the positive ionization mode with selected reaction monitoring (Ang1 m/z 649.0-->784.0; IS m/z 641.9-->770.4). RESULTS The assay was linear over the range 2.5-500 ng Ang1/mL, which corresponded to a limit of detection (signal-to-noise ratio of 3:1) of PRA of 0.14 ng Ang1. mL-1. h-1. The imprecision (CV) of the assay at PRA values of 26.1, 13.5, 3.2, and 0.78 ng Ang1. mL-1. h-1 was 7.0%, 7.0%, 15%, and 11%, respectively. Absolute recoveries were 92.3% (Ang1) and 87.4% (IS). Incubation times of 3 h vs 18 h in the PRA assay gave good agreement at PRA <2 ng Ang1. mL-1. h-1, but samples with a PRA of 2-5 ng Ang1. mL-1. h-1 gave lower PRA results after incubation for 18 h than after 3 h. We compared the HPLC-ESI-MS/MS assay and an RIA for the determination of PRA, with PRA incubation times of 3 h and 1.5 h, respectively. The mean PRA based on RIA of Ang1 was higher than that obtained using HPLC-ESI-MS/MS. CONCLUSION The HPLC-ESI-MS/MS method allows sensitive and specific measurement of PRA. The higher activities measured with the RIA method highlight its potential for overestimation of PRA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry

A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography&ndash;tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

Determination of 5-fluorouracil in plasma with HPLC-tandem mass spectrometry.

In this article, we describe a fast and specific method to measure 5FU with HPLC tandem-mass spectrometry. Reversed-phase HPLC was combined with electrospray ionization tandem mass spectrometry and detection was performed by multiple-reaction monitoring. Stable-isotope-labeled 5FU (1,3-15N2-5FU) was used as an internal standard. 5FU was measured within a single analytical run of 16 min with a l...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 5  شماره 

صفحات  -

تاریخ انتشار 1999