Magnetic Field Tomography

نویسندگان

  • Ph. W. Courteille
  • S. R. Muniz
  • K. Magalhães
  • R. Kaiser
  • L. G. Marcassa
  • V. S. Bagnato
چکیده

Neutral atoms may be trapped via the interaction of their magnetic dipole moment with magnetic field gradients. One of the possible schemes is the cloverleaf trap. It is often desirable to have at hand a fast and precise technique for measuring the magnetic field distribution. We use for instantaneous imaging the equipotential lines of the magnetic field a diagnostic tool which is based on spatially resolved observation of the fluorescence emitted by a hot beam of sodium atoms crossing a thin slice of resonant laser light within the magnetic field region to be investigated. The inhomogeneous magnetic field spatially modulates the resonance condition between the Zeeman-shifted hyperfine sublevels and the laser light and therefore the amount of scattered photons. We apply this technique for mapping the field of our cloverleaf trap in three dimensions under various conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Employing dual frequency phase sensitive demodulation technique to improve the accuracy of voltage measurement in magnetic induction tomography and designing a labratoary prototype

Magnetic induction tomography (MIT) is a promising modality for noninvasive imaging due to its contactless technology. Being a non-contact safe imaging technique, MIT has been an appropriate method in compare to other electrical tomography. In this imaging method, a primary magnetic field is applied by excitation coils to induce eddy currents in the material to be studied and a secondary magnet...

متن کامل

Effect of uniform magnetic field on dose distribution in the breast radiotherapy

Background: To reduce the dose to normal tissues surrounding the treated breast, a uniform magnetic field was used within a humanoid phantom in breast radiotherapy. Materials and Methods: Monte Carlo simulations were performed with GEANT4, irradiating humanoid phantoms in a magnetic field. To reconstruct phantoms, computed tomography (CT) data slices of four patients were used for the Monte Car...

متن کامل

Application of computed tomography and magnetic resonance imaging fusion images for delineating gross tumor volume in three-dimensional conformal radiotherapy of nasopharyngeal carcinoma

Background: To evaluate computed tomography (CT) and magnetic resonance imaging (MRI) fusion images for delineating gross tumor volume (GTV) in three-dimensional conformal radiotherapy (3D-CRT) of nasophanrygeal carcinoma (NPC), and compare treatment outcomes between CT- and CT+MRI-based targets. Materials and Methods: A total of 120 NPC patients treated with 3D-CRT were included, in which, 60 ...

متن کامل

Phase-resolved spectral-domain magnetomotive optical coherence tomography

We advance the magnetomotive-optical coherence tomography (MM-OCT) technique for detecting displacements of magnetic nanoparticles embedded in tissue-like phantoms by using apmplitude and phase-resolved methods with spectral-domain optical coherence tomography (SD-OCT). The magnetomotion is triggered by the external, noninvasive application of a magnetic field. We show that both amplitude and p...

متن کامل

Magnetoacoustic Tomography with Magnetic Stimulation (MAT-MS)

We have proposed a new imaging modality, magnetoacoustic tomography with magnetic stimulation (MAT-MS) to image the electrical impedance distribution. In this paper we report out pilot experimental study. In MAT-MS, the tissue is put in a static magnetic field and a pulsed ( s μ ) magnetic field. The pulsed magnetic field induces eddy current in the tissue. Consequently, the tissue will emit ul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001