How to Minimize Rotational Conflict between Femoral & Tibial Component in Total Knee Arthroplasty: The Use of Femoro-Tibial Axial Synchronizer (Linker)

نویسندگان

  • Jai-Gon Seo
  • Young-Wan Moon
  • Sang-Min Kim
  • Sang-Hoon Park
چکیده

PURPOSE The purpose of this study was to investigate the correlation between rotational axes of femur and tibia with the use of Linker. MATERIALS AND METHODS This study was carried out from August 2009 to February 2010 on 54 patients (106 knees), who were diagnosed with simultaneous bilateral total knee arthroplasty. With the use of postoperative computed tomography scans, it was investigated how much the rotational angle of femoral and tibial components matched. RESULTS The tibial component was internally rotated for the femoral component at an angle of 0.8°. The femoral component was externally rotated for the surgical transepicondylar axis (TEA) at an angle of 1.6 (range: from 4.8° of internal rotation to 7.9° of external rotation, SD=2.2°), and the tibial component was externally rotated for the surgical TEA at an average angle of 0.9 (range: from 5.1° of internal rotation to 8.3° of external rotation, SD=3.1°). CONCLUSION The femoro-tibial synchronizer helped to improve the orientation and positioning of both femoral component and tibial component, and also increase the correlation of the rotational axes of the two components.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Micromotion at the tibial plateau in primary and revision total knee arthroplasty: fixed versus rotating platform designs.

OBJECTIVES Initial stability of tibial trays is crucial for long-term success of total knee arthroplasty (TKA) in both primary and revision settings. Rotating platform (RP) designs reduce torque transfer at the tibiofemoral interface. We asked if this reduced torque transfer in RP designs resulted in subsequently reduced micromotion at the cemented fixation interface between the prosthesis comp...

متن کامل

Is There a Gold Standard for Rotational Alignment of the Tibial Component During

INTRODUCTION A successful total knee arthroplasty (TKA) is dependent on many factors, but component alignment is particularly critical. Aligning the femoral component parallel to the transepicondylar axis is generally regarded as the optimal rotational position, since it has been shown to produce a balanced joint, optimize patellar tracking, and minimize patellofemoral shear forces [1,2] the fe...

متن کامل

Combined Rotational Alignment Change after Total Knee Arthroplasty in Different Tibial Component Designs: Implications for Optimal Tibial Component Rotational Alignment

Purpose The rotational alignment of the femoral and tibial components is closely related to the results after total knee arthroplasty (TKA). In this study, we measured the combined rotational alignment change (ΔCR) after TKA and compared the different influence of symmetric and asymmetric tibial component designs on the combined rotational alignment. Materials and Methods Eighty-four patients...

متن کامل

Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations

BACKGROUND Clinical consequences of alignment errors in total knee replacement (TKR) have led to the rigorous evaluation of surgical alignment techniques. Rotational alignment in the transverse plane has proven particularly problematic, with errors due to component malalignment relative to bone anatomic landmarks and an overall mismatch between the femoral and tibial components' relative positi...

متن کامل

Malrotation causing patellofemoral complications after total knee arthroplasty.

Thirty patients with isolated patellofemoral complications after total knee arthroplasty were compared with 20 patients with well functioning total knee replacements without patellofemoral complications. The epicondylar axis and tibial tubercle were used as references on computed tomography scans to measure quantitatively rotational alignment of the femoral and tibial components. The group with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 56  شماره 

صفحات  -

تاریخ انتشار 2015