Assessment of I-125 seed implant accuracy when using the live-planning technique for low dose rate prostate brachytherapy
نویسندگان
چکیده
BACKGROUND Low risk prostate cancers are commonly treated with low dose rate (LDR) brachytherapy involving I-125 seeds. The implementation of a 'live-planning' technique at the Royal Adelaide Hospital (RAH) in 2007 enabled the completion of the whole procedure (i.e. scanning, planning and implant) in one sitting. 'Live-planning' has the advantage of a more reliable delivery of the planned treatment compared to the 'traditional pre-plan' technique (where patient is scanned and planned in the weeks prior to implant). During live planning, the actual implanted needle positions are updated real-time on the treatment planning system and the dosimetry is automatically recalculated. The aim of this investigation was to assess the differences and clinical relevance between the planned dosimetry and the updated real-time implant dosimetry. METHODS A number of 162 patients were included in this dosimetric study. A paired t-test was performed on the D90, V100, V150 and V200 target parameters and the differences between the planned and implanted dose distributions were analysed. Similarly, dosimetric differences for the organs at risk (OAR) were also evaluated. RESULTS Small differences between the primary dosimetric parameters for the target were found. Still, the incidence of hotspots was increased with approximately 20% for V200. Statistically significant increases were observed in the doses delivered to the OAR between the planned and implanted data; however, these increases were consistently below 3% thus probably without clinical consequences. CONCLUSIONS The current study assessed the accuracy of prostate implants with I-125 seeds when compared to initial plans. The results confirmed the precision of the implant technique which RAH has in place. Nevertheless, geographical misses, anatomical restrictions and needle displacements during implant can have repercussions for centres without live-planning option if dosimetric changes are not taken into consideration.
منابع مشابه
Salvage low-dose-rate 125I partial prostate brachytherapy after dose-escalated external beam radiotherapy
PURPOSE To report outcomes on 5 patients treated with salvage partial low-dose-rate (LDR) 125-iodine ((125)I) permanent prostate seed brachytherapy (BT) for biopsy-proven locally persistent prostate cancer, following failure of dose-escalated external beam radiotherapy (EBRT). MATERIAL AND METHODS A retrospective review of the Fox Chase Cancer Center prostate cancer database identified five p...
متن کاملThe effect of tissue composition of the prostate on the dose calculation for 125 I brachytherapy
P Introduction ermanent seed-implant treatment using I radionuclide is currently a standard procedure for early-stage prostate carcinoma, and the method is now considered comparable to external-beam radiation therapy and prostatectomy. As with external beam radiation therapy, permanent seed implant treatment of the prostate requires a dose-outcome correction, pointing out the importance of the ...
متن کاملEvaluation of the MIM Symphony treatment planning system for low‐dose‐rate‐ prostate brachytherapy
MIM Symphony is a recently introduced low-dose-rate prostate brachytherapy treatment planning system (TPS). We evaluated the dosimetric and planning accuracy of this new TPS compared to the universally used VariSeed TPS. For dosimetric evaluation of the MIM Symphony version 5.4 TPS, we compared dose calculations from the MIM Symphony TPS with the formalism recommended by the American Associatio...
متن کاملIodine-125 brachytherapy for localized prostate cancer and urinary morbidity: a prospective comparison of two seed implant methods-preplanning and intraoperative planning.
OBJECTIVES To compare morbidity between two currently used iodine-125 seed implantation techniques for the treatment of localized prostate cancer. METHODS Iodine-125 brachytherapy was used in 300 consecutive men with localized prostate cancer. Two seed implant techniques were used: preplanning, using preloaded needles, and intraoperative planning, using a Mick applicator. A comparison was mad...
متن کاملClinical implementation of a digital tomosynthesis-based seed reconstruction algorithm for intraoperative postimplant dose evaluation in low dose rate prostate brachytherapy.
PURPOSE The low dose rate brachytherapy procedure would benefit from an intraoperative postimplant dosimetry verification technique to identify possible suboptimal dose coverage and suggest a potential reimplantation. The main objective of this project is to develop an efficient, operator-free, intraoperative seed detection technique using the imaging modalities available in a low dose rate bra...
متن کامل