Optical signals from neurons with internally applied voltage-sensitive dyes.

نویسندگان

  • S Antić
  • D Zecević
چکیده

We carried out experiments to monitor optically the generation and spread of action potentials and subthreshold potentials in the processes of individual neurons in ganglia of the snail, Helix aspersa. The neurons were selectively stained by intracellular pressure injection of voltage-sensitive dyes. Optical signals were detected by a system for fast, multiple-site optical monitoring, utilizing a silicon photodiode array. After testing 30 voltage-sensitive dyes using absorption, we concluded that this mode was probably not sensitive enough to allow monitoring neuronal signals from distal processes. Satisfactory signals were obtained in fluorescence measurements using a newly synthesized styryl dye, JPW1114, specifically designed for intracellular application. There was an improvement in sensitivity (as defined by the signal-to-noise ratio) by a factor of about 50 over previously reported absorption and fluorescence signals from neuronal processes stained by either intra- or extracellular application of dyes. Recordings with good signal-to-noise ratio and adequate spatial and temporal resolution were obtained simultaneously from the cell body and long axonal branches. From this data, the site of action potential initiation was determined. Also, the propagation velocity of the action potential was calculated for different axonal segments; the results suggest that different regions have different velocities ranging from 0.53 m/sec to 0.07 m/sec. The present sensitivity was adequate to allow the recording of a 10 mV hyperpolarizing electrotonic response along axonal branches and to observe directly the decline of this passive response with distance from the site of stimulation. Relatively modest improvements in sensitivity will allow systematic analyses of the spread and summation of synaptic potentials in individual neurons.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of Voltage - Sensitive Dyes and Optical

-Understanding the spatio-temporal features of the information processing occurring in any complex neural structure requires the monitoring and analysis of the activity in populations of neurons. Electrophysiological and other mapping techniques have provided important insights into the function of neural circuits and neural populations in many systems. However, there remain limitations with th...

متن کامل

Imaging cortical electrical stimulation in vivo: fast intrinsic optical signal versus voltage-sensitive dyes.

We applied high-temporal-resolution optical imaging utilizing both the fast intrinsic optical signal (fIOS) and voltage-sensitive dyes (VSDs) to observe the spatiotemporal characteristics of rat somatosensory cortex during electrical stimulation. We find that changes in both the fIOS and VSD signals occur rapidly (<30 ms) after the stimulus is applied, suggesting that both membrane depolarizati...

متن کامل

High-speed, random-access fluorescence microscopy: II. Fast quantitative measurements with voltage-sensitive dyes.

An improved method for making fast quantitative determinations of membrane potential with voltage-sensitive dyes is presented. This method incorporates a high-speed, random-access, laser-scanning scheme (Bullen et al., 1997. Biophys. J. 73:477-491) with simultaneous detection at two emission wavelengths. The basis of this ratiometric approach is the voltage-dependent shift in the emission spect...

متن کامل

Arsenazo III and antipyrylazo III calcium transients in single skeletal muscle fibers

The metallochrome calcium indicators arsenazo III and antipyrylazo III have been introduced individually into cut single frog skeletal muscle fibers from which calcium transients have been elicited either by action potential stimulation or by voltage-clamp pulses of up to 50 ms in duration. Calcium transients recorded with both dyes at selected wavelengths have similar characteristics when elic...

متن کامل

Combining Uncaging Techniques with Patch-Clamp Recording and Optical Physiology

Patch-clamp recording is a powerful approach to monitoring membrane electrical activity with high temporal resolution. However, the spatial resolution of patch-clamp recording in a distributed structure such as a neuron or a brain slice is limited by the fact that each electrode records from just one point, making recording from more than a very small number of points impractical. An approach t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of neuroscience : the official journal of the Society for Neuroscience

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 1995