Quantitation of psilocin in human plasma by high-performance liquid chromatography and electrochemical detection: comparison of liquid-liquid extraction with automated on-line solid-phase extraction.
نویسندگان
چکیده
Two modifications of the HPLC-ED method with respect to extraction procedure used have been developed for psilocin, the active metabolite of psilocybin, in human plasma using either liquid-liquid extraction (LLE) or automated on-line solid-phase extraction (on-line SPE). Each type of the sample preparation required a different HPLC system followed by electrochemical detection at 650 to 675 mV. The limit of quantitation of both modifications was 10 ng/ml psilocin. There was no significant difference observable between the LLE and the on-line SPE in terms of method standard deviation (LLE 1.82%, on-line SPE 1.13%) and the analytical results. However, the advantages of on-line SPE in addition to different selectivity were less manual effort, smaller plasma volumes of 400 microl (LLE 2 ml) and a recovery of psilocin in human plasma of nearly 100% (LLE 88%). In contrast to a previous procedure both methods were rapid, simple and reliable and yielded high plasma recoveries. They were used successfully in the quantitation of psilocin in plasma samples obtained from healthy volunteers after p.o. administration of 0.2 mg psilocybin per kg body mass. Plasma concentration curves and pharmacokinetic parameters were calculated.
منابع مشابه
On-line coupling of automated solid-phase extraction with high-performance liquid chromatography and electrochemical detection. Quantitation of oxidizable drugs of abuse and their metabolites in plasma and urine.
The concentration effect of automated on-line solid-phase extraction (SPE) in combination with HPLC and very sensitive electrochemical detection was employed for the determination of N-ethyl-4-hydroxy-3-methoxy-amphetamine (HMEA, the main metabolite of the ecstasy analogue MDE), delta 9-tetrahydrocannabinol (THC) and 11-nor-delta 9-tetrahydrocannabinol-carboxylic acid (THC-COOH) in plasma and u...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER
An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...
متن کاملVortex-Assisted Inverted Dispersive Liquid-Liquid Microextraction of Naproxen from Human Plasma and Its Determination by High-Performance Liquid Chromatography
Extraction and determination of naproxen from human plasma were performed using Vortex-Assisted Inverted Dispersive Liquid-Liquid MicroExtraction (VA−IDLLME) and High-Performance Liquid Chromatography (HPLC). The parameters affecting extraction recovery such as type and volume of extraction and disperser solvents, pH of sample solution, stirring rate, extraction time and salt addition were ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. B, Biomedical sciences and applications
دوره 709 2 شماره
صفحات -
تاریخ انتشار 1998