A Virtual Supply Airflow Rate Meter in Rooftop Air Conditioning Units

نویسندگان

  • Daihong Yu
  • Haorong Li
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Inexpensive Retrofit Technology for Reducing Peak Power Demand in Small and Medium Commercial Buildings

This article describes a low cost retrofit technology that uses collective control of multiple rooftop air conditioning units to reduce the peak power consumption of small and medium commercial buildings. The proposed control uses a thermal model of the building and air conditioning units to select an operating schedule for the air conditioning units that maintains a temperature set point subje...

متن کامل

Effect of Condenser Air Flow on the Performance of Split Air Conditioner

Split air conditioning units are usually used for small and medium scale residential buildings. Therefore, more energy efficiency and lower cost are needed along with reliable control for the air conditioning units. An experimental investigation has been carried out to study the performance of a direct expansion air conditioning (A/C) unit having a variable speed condenser fan. The modulation o...

متن کامل

Virtual Power Consumption and Cooling Capacity Virtual Sensors for Rooftop Units

Implementation of advanced controls and diagnostic features in small commercial buildings typically requires realtime monitoring of the energy flows, such as the power consumption and cooling capacity of rooftop units. However, these measurements are expensive and therefore limit the application of these advanced features. In order to lower the measurement cost, virtual sensing technology for r...

متن کامل

Simulation of Thermal Distribution and Airflow for Efficient Energy Consumption in a Small Data Centers

Data centers have become ubiquitous in the last few years in an attempt to keep pace with the processing and storage needs of the Internet and cloud computing. The steady growth in the heat densities of IT servers leads to a rise in the energy needed to cool them, and constitutes approximately 40% of the power consumed by data centers. However, many data centers feature redundant air conditioni...

متن کامل

Design and Implementation of Air Conditioning System in Operating Room

The system is air conditioning system in operating room. The main objective of the system was implemented to provide air balance and temperature necessary conditions and to control airflow system for ventilation units in operating room. The operation room can be controlled with fuzzy expert system and describes the desired outputs. Input parameters such as temperature, humidity, oxygen and part...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016