Noninvasive Fetal Electrocardiography Part II: Segmented-Beat Modulation Method for Signal Denoising
نویسندگان
چکیده
BACKGROUND Fetal well-being evaluation may be accomplished by monitoring cardiac activity through fetal electrocardiography. Direct fetal electrocardiography (acquired through scalp electrodes) is the gold standard but its invasiveness limits its clinical applicability. Instead, clinical use of indirect fetal electrocardiography (acquired through abdominal electrodes) is limited by its poor signal quality. OBJECTIVE Aim of this study was to evaluate the suitability of the Segmented-Beat Modulation Method to denoise indirect fetal electrocardiograms in order to achieve a signal-quality at least comparable to the direct ones. METHOD Direct and indirect recordings, simultaneously acquired from 5 pregnant women during labor, were filtered with the Segmented-Beat Modulation Method and correlated in order to assess their morphological correspondence. Signal-to-noise ratio was used to quantify their quality. RESULTS Amplitude was higher in direct than indirect fetal electrocardiograms (median:104 µV vs. 22 µV; P=7.66·10-4), whereas noise was comparable (median:70 µV vs. 49 µV, P=0.45). Moreover, fetal electrocardiogram amplitude was significantly higher than affecting noise in direct recording (P=3.17·10-2) and significantly in indirect recording (P=1.90·10-3). Consequently, signal-to-noise ratio was initially higher for direct than indirect recordings (median:3.3 dB vs. -2.3 dB; P=3.90·10-3), but became lower after denoising of indirect ones (median:9.6 dB; P=9.84·10-4). Eventually, direct and indirect recordings were highly correlated (median: ρ=0.78; P<10-208), indicating that the two electrocardiograms were morphologically equivalent. CONCLUSION Segmented-Beat Modulation Method is particularly useful for denoising of indirect fetal electrocardiogram and may contribute to the spread of this noninvasive technique in the clinical practice.
منابع مشابه
A novel technique for fetal heart rate estimation from Doppler ultrasound signal
BACKGROUND The currently used fetal monitoring instrumentation that is based on Doppler ultrasound technique provides the fetal heart rate (FHR) signal with limited accuracy. It is particularly noticeable as significant decrease of clinically important feature - the variability of FHR signal. The aim of our work was to develop a novel efficient technique for processing of the ultrasound signal,...
متن کاملA Hybrid EMD-Kurtosis Method for Estimating Fetal Heart Rate from Continuous Doppler Signals
Monitoring of fetal heart rate (FHR) is an important measure of fetal wellbeing during the months of pregnancy. Previous works on estimating FHR variability from Doppler ultrasound (DUS) signal mainly through autocorrelation analysis showed low accuracy when compared with heart rate variability (HRV) computed from fetal electrocardiography (fECG). In this work, we proposed a method based on emp...
متن کاملSegmented Modeling of ECG Signal by Using Hermite Basis Function
In this paper, a new technique of modeling for the approximation of entire ECG signal is presented. The proposed method is applied on four different ECG beats. In most modeling methods, best approximation for the important part of the signal is done. But the entire ECG signal is important for the diagnosis of different diseases. The proposed method exploit the importance of whole ECG waves by p...
متن کاملA New Method for Fetal Electrocardiogram Denoising Using Blind Source Separation and Empirical Mode Decomposition
1 “Politehnica” University of Bucharest, Applied Electronics and Information Engineering Department, E-mail: [email protected], rodica. [email protected]. 2 “Carol Davila” University of Medicine and Pharmacy, Obstretics and Gynecology Department, Bucharest, Romania, E-mail: ilinca. [email protected]. A NEW METHOD FOR FETAL ELECTROCARDIOGRAM DENOISING USING BLIND SOURCE SEPARATION AND EMPIRIC...
متن کاملExtracting fetal heart signal from noisy maternal ECG by multivariate singular spectrum analysis
Fetal heart rate and its beat-to-beat variability are two important indications about the health and condition of the fetus. The observed maternal electrocardiogram (ECG) signal consists of mother heart signal and fetal heart signal and is often very noisy. In this paper, we propose a multivariate singular spectrum analysis (MSSA) for extracting and separating the mother heart signal, the fetal...
متن کامل