Precise Synchronization of Phasor Measurements in Electric Power Systems

نویسنده

  • A. G. Phadke
چکیده

Phasors representing positive sequence voltages and currents ih a power network are the most important parameters i n several monitoring, control, and protection functions i n interconnected electric power networks. Recent advances in computer relaying have led to very efficient and accurate phasor measurement systems. When the phasors to be measured are separated by hundrea of miles, i t becomes necessary to synchronize the mesurement processes, so that a consistent description of the state of the power system can be established. GPS transmissions offer an ideal source for synchronization of phasor measurements. The paper describes the concept and implementation of this technique. Several uses of synchronized phasor measurements are also described. Among these are improved state estimation algorithms, state estimator enhancements, dynamic state estimates, improved control techniques, and improved protection concepts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using of Clustering Techniques in Optimal Placement of Phasor Measurements Units

The phasor measurement unit (PMU) is considered to be one of the most important measuring devices in the future of power systems. The distinction comes from its unique ability to provide synchronized phasor measurements of voltages and currents from widely dispersed locations in an electric power grid. This paper proposes an algorithm based on the clustering techniques for solving the optimal P...

متن کامل

Neuro-Fuzzy Based Algorithm for Online Dynamic Voltage Stability Status Prediction Using Wide-Area Phasor Measurements

In this paper, a novel neuro-fuzzy based method combined with a feature selection technique is proposed for online dynamic voltage stability status prediction of power system. This technique uses synchronized phasors measured by phasor measurement units (PMUs) in a wide-area measurement system. In order to minimize the number of neuro-fuzzy inputs, training time and complication of neuro-fuzzy ...

متن کامل

Analysis of Synchronization and Accuracy of Synchrophasor Measurements by

i ABSTRACT In electric power systems, phasor measurement units (PMUs) are capable of providing synchronized voltage and current phasor measurements which are superior to conventional measurements collected by the supervisory control and data acquisition (SCADA) system in terms of resolution and accuracy. These measurements are known as synchrophasor measurements. Considerable research work has ...

متن کامل

An Implementation of Two-stage Hybrid State Estimation with Limited Number of Pmu

State estimation is an important tool for power system supervision and control and the related applications. Based on the redundant measurements taken in the network, state estimation provides the most likely state of the power system. Conventional measurements were collected by the SCADA system and the measurement chain did not allow measurement synchronization. A disadvantage is that due to t...

متن کامل

A PLL Scheme for Synchronization with Grid Voltage Phasor in Active Power Filter Systems

Voltage source inverters connected to the grid in applications such as active power filters require synchronization with the grid voltage. Since in practice the grid voltage can be unbalanced and distorted, but the operation of the whole active filter control system is strongly dependant on precise estimation of grid voltage phase, the fundamental positive sequence phasor of the grid voltage ha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009