Measuring Micron Size Beams in the SLC Final Focus
نویسندگان
چکیده
A pair of high resolution wire scanners have been built and installed in the SLC final focus. The final focus optics uses a set of de-magnifying telescopes, and an ideal location for a beam size monitor is at one of the magnified image points of the interaction point. The image point chosen for these scanners is in the middle of a large bend magnet. The design beam spots here are about 2 microns in the vertical and 20 microns in the horizontal plane. The scanners presented a number of design challenges. In this paper we discuss the mechanical design of the scanner, and fabrication techniques of its ceramic wire support card which holds many 4 and 7 um carbon wires. Accurate motion of the wire during a scan is critical. In this paper we describe tests of stepper motors, gear combinations, and radiation hardened encoders needed to produce the required motion with a step resolution of 80 nanometers. Also presented here are the results of scattered radiation detector placement studies carried out to optimize the signal from the 4 micron wires. Finally, we present measurements from the scanner. INTRODUCTION Wire scanner beam size monitors are used throughout the Stanford Linear Collider (SLC) to make beam profile and emittance measurements.[1,2]. After the conclusion of the 1993 SLC run, the final focus optics were upgraded to provide improved chromatic correction. As part of this upgrade, five new scanners were added to both the north and south final focus. One of these scanners is located at an image of the interaction point (IP), and it provides a direct estimate of the vertical beam size at the IP. Because of its location, this scanner plays a particularly important role in measuring the properties of the incoming beam and the performance of the final focus optics. At this wire scanner, the design ßx and ßy are small, and the horizontal dispersion is a few centimeters. The aspect ratio of the beam at this scanner is ten to one. The primary goal of this scanner is to measure the vertical beam size and the x-y coupling to within 5% at the full SLC repetition rate and current. MECHANICAL DESIGN The location of the IP image is at the center of a large bend magnet. Two types of scanner installations were considered. One design required cutting the steel of the magnet in half, moving the sections apart and building separate coils for each of the resulting halves. A standard SLC wire scanner design, [1] which moves at 45 ̊ with respect to the horizontal, would have been used. Another option required boring a vertical hole through the middle of the magnet. A wire scanner with a * Work supported by Department of Energy contract DE–AC03–76SF00515. ** Operated for the U.S. Department of Energy under Contract No. DE–ACO4–76DP00613. vertical motion was needed for this design. The impact of the magnet modifications, the performance required of the wire scanner, and the costs of each design were considered. Given that a scanner with vertical motion can make all the required measurements, and that calculations of the effects from the hole in the magnet indicated only minor field distortion, the scanner with the vertical motion was chosen. Measuring the vertical beam size is done using a horizontal wire. The x-y coupling and the x beam size measurements are obtained by using two sets of wires; one at ±5 degrees and another at ±15 degrees with respect to the horizontal wire. The angles of theses wires with respect to the beam must be known to ±3.0 milli radians in order to maintain the required measurement accuracy. The scanner is built so that the angle of the wires with respect to the beam could be measured and adjusted after the scanner installation. The wires are accurately fixed to a ceramic fork which was indexed to surveyor tooling balls on the top of the scanner. Adjusting the angle of the wires is accomplished by having the slide and shaft assembly mounted on a circular saddle. The scanner can be rolled until the wires are at the correct angle with respect to the beam. WIRE CARD FABRICATION The wire scanner card is fabricated from a 4.50 x 3.75 x 0.27 inch thick 99.5% alumina substrate (a herman). Machining the herman is done using a CO2 laser. Parts of the herman are cut away to reveal the outline of the wire card, a two tine fork. The wire card is left attached to the herman in several locations. This provides a means of handling the card without risk of contamination and aids in the installation of the carbon wires. Tooling holes in the card are ground to exact tolerances using a diamond jig grinding machine. These holes are used to mate the wire card precisely to the shaft of the wire scanner. After the wires are attached, the card is scored along the attachment points and broken out of the herman. V-shaped grooves shown in Fig. 1 were machined into the surface of the card to precisely locate the carbon wires. The grooves are approximately 14 microns wide and 20 microns deep. The machining was performed using a excimer laser with a high precision X-Y table. Since the location of the grooves are referenced to the card's tooling holes, the position of each wire on the wire scanner is known. Figure 1. A seven micron carbon wire is positioned in a V groove cut in an alumina substrate. Attaching the wires to the fork proved to be difficult. The initial approach was to place a mask over the card leaving only the tines exposed. Titanium and then palladium was sputtered over the wire filled grooves. It was believed that this would seal the wires in place with a "blanket" of metalization. Two problems prevented this technique from working. The metalization did not adhere to the tines in the areas where the excimer laser machining was performed. This was found to be caused by a fine non-adhering alumina particulate[3] left behind after the excimer laser machining. This problem was solved by refiring the card at 1400 ̊C before the wires were placed in the grooves. The particulates were sintered to the card, providing a solid substrate for the metalization process. The metallization adhered to the wires and the tines, but cracks developed between them, and the wires still pulled easily out of the grooves. To solve this, the wires were soldered into the grooves using a 48.5% Sn / 51.5% In solder preform. The solder was reflowed in a nitrogen belt furnace using no flux. A finished wire card is shown in Fig. 2. Figure 2. A finished wire card is shown above. The ±15, ±5, and 0 degree wires, and the diamond ground holes which precisely position the card on the shaft the wire scanner are shown. WIRE SCANNER MOTION Standard SLC wire scanners use a stepper motor with 200 full steps per revolution. The motor drives a ball screw with a lead of 2mm per revolution, producing a linear motion of 10 microns per full step. The 2 micron vertical spots at the scanner require a much finer step resolution. Microstepping divides full steps of a stepping motor into 125 smaller microsteps. For this scanner, microstepping improved the step resolution to 80 nanometers. A test facility was constructed to measure the uniformity of the motion. A linear optical encoder with a resolution of 50 nanometers was used to measure slide motion.[4]. A least squares linear fit to the encoder data was performed and the residual from the fit to the data is shown in Fig.3. Depending on which part of a normal step a two micron beam sampled, the measurement error could be as large as 30%. These errors were too large to meet the measurement goals for these scanners. Three attempts were made to reduce this error. The microstepping module used for the tests has a feature that resets the motor to the nearest full step. This forces the scan to begin from the start of a full step. It was hoped that the error would be similar enough from one scan to the next to allow a correction. Unfortunately, the motion varied at different motor speeds and different slide positions and the corrected data had an error equal or larger to the original. Another attempt at
منابع مشابه
ar X iv : p hy si cs / 0 01 00 08 3 O ct 2 00 0 SLC Final Performance and Lessons
The Stanford Linear Collider (SLC) was the first prototype of a new type of accelerator, the electronpositron linear collider. Many years of dedicated effort were required to understand the physics of this new technology and to develop the techniques for maximizing performance. Key issues were emittance dilution, stability, final beam optimization and background control. Precision, non-invasive...
متن کاملSLC Final Performance and Lessons
The Stanford Linear Collider (SLC) was the first prototype of a new type of accelerator, the electronpositron linear collider. Many years of dedicated effort were required to understand the physics of this new technology and to develop the techniques for maximizing performance. Key issues were emittance dilution, stability, final beam optimization and background control. Precision, non-invasive...
متن کاملResults from the Final Focus Test Beam
First experimental results from the Final Focus Test Beam (FFTB) are given in this report. The FFTB has been constructed as a prototype for the final focus system of a future TeV-scale electron-positron linear collider. The vertical dimension of the 47 GeV electron beam from the SLAC linac has been reduced at the focal point of the FFTB by a demagnification of 320 to a beam height of approximat...
متن کاملBeam Dispersion Measurements with Wire Scanners in the SLC Final Focus Systems
A method is described to make a direct measurement of the horizontal and vertical momentum dispersion of the electron and positron beams as they pass through the chromatic correction sections (CCS) of tbe SLC final focus systems. The metbod is advantageous since it cleanly separates betatron components of the beam size from dispersive components, can be measured during standard colliding beams ...
متن کاملLimitations of Interaction-point Spot-size Tuning at the Slc
At the Stanford Linear Collider (SLC), the interactionpoint spot size is minimized by repeatedly correcting, for both beams, various low-order optical aberrations, such as dispersion, waist position or coupling. These corrections are performed about every 8 hours, by minimizing the IP spot size while exciting different orthogonal combinations of final-focus magnets. The spot size itself is dete...
متن کاملFocusing of submicron beams for TeV-scale e+e- linear colliders.
First experimental results from the Final Focus Test Beam (FFTB) are reported. The vertical dimension of a 47 GeV electron beam from the SLAC linac has been reduced at the focal point of the FFTB by a demagnification of 320 to a beam height of approximately 70 nanometers. One of the challenges to the development of TeV-scale e+e’ linear colliders is to focus particle beams to extremely small si...
متن کامل