Noninvasive continuous versus intermittent arterial pressure monitoring: evaluation of the vascular unloading technique (CNAP device) in the emergency department
نویسندگان
چکیده
BACKGROUND Monitoring cardiovascular function in acutely ill patients in the emergency department (ED) is of paramount importance. Arterial pressure (AP) is usually monitored using intermittent oscillometric measurements with an upper arm cuff. The vascular unloading technique (VUT) allows continuous noninvasive AP monitoring. In this study, we compare continuous AP measurements obtained by VUT with intermittent oscillometric AP measurements in ED patients. In addition, we aimed to investigate whether continuous noninvasive AP monitoring allows detection of relevant hypotensive episodes that might be missed with intermittent AP monitoring. METHODS In a German university hospital, 130 ED patients who required AP monitoring were analyzed in this prospective method comparison study. Continuous AP monitoring was performed using VUT (CNAP technology; CNSystems Medizintechnik AG, Graz, Austria) over a 2-hour period. The oscillometric AP values were recorded simultaneously every 15 minutes for the comparison of both methods. For statistical evaluation, Bland-Altman plots accounting for repeated AP measurements per individual were used. RESULTS The mean difference (±standard deviation) between AP measurements obtained by VUT and oscillometric AP measurements was -5 mmHg (±22 mmHg) for systolic AP (SAP), -2 mmHg (±15 mmHg) for diastolic AP (DAP), and -6 mmHg (±16 mmHg) for mean AP (MAP), respectively. In the interval between two oscillometric measurements, the VUT device detected hypotensive episodes (≥4 minutes) defined as either SAP <90 mmHg or MAP <65 mmHg in 30 patients and 16 patients, respectively. In 11 (SAP <90 mmHg) and 6 (MAP <65 mmHg) of these patients, hypotension was also detected by the subsequent intermittent oscillometric AP measurement. CONCLUSIONS VUT using the CNAP system for noninvasive continuous AP measurement shows reasonable agreement with intermittent oscillometric measurements in acutely ill ED patients. Continuous AP monitoring allows immediate recognition of clinically relevant hypotensive episodes, which are missed or only belatedly recognized with intermittent AP measurement.
منابع مشابه
Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy
INTRODUCTION Close monitoring of arterial blood pressure (BP) is a central part of cardiovascular surveillance of patients at risk for hypotension. Therefore, patients undergoing diagnostic and therapeutic procedures with the use of sedating agents are monitored by discontinuous non-invasive BP measurement (NIBP). Continuous non-invasive BP monitoring based on vascular unloading technique (CNAP...
متن کاملRadial artery tonometry: moderately accurate but unpredictable technique of continuous non-invasive arterial pressure measurement.
Radial artery tonometry provides continuous measurement of non-invasive arterial pressure (CNAP) by a sensor positioned above the radial artery. An inflatable upper arm cuff enables intermittent oscillometric calibration. CNAP was compared with invasive radial artery pressure recordings from the opposite wrist in 22 high-risk surgical patients with an inter-arm oscillometric mean arterial press...
متن کاملComparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study
Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...
متن کاملAccuracy of continuous noninvasive arterial pressure monitoring in living-liver donors during transplantation.
OBJECTIVES Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monit...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کامل