The Accuracy of Myocardial T2-Mapping Techniques
نویسندگان
چکیده
Objective: 1. To evaluate different pulse sequence options available for T2 Mapping of human myocardium vis-à-vis accuracy of T2 measurements in phantoms. 2. To propose a practical approach to T2 evaluation that can be used in clinical setting to distinguish tissues with T2 differences 3. To get a range of values for human myocardial T2 values using the most accurate and practical approach. 4. To study the inter-subject variability of myocardial T2 values in healthy subjects. Background: The MR T2 relaxation time of human myocardium is an important parameter in detection of myocardial edema and inflammation. These pathologic changes in myocardium can be detected using either a T2 Weighted (T2W) sequence or by directly quantifying the T2 values in a T2 Map. Past literature has reported a wide range of normal myocardial T2 values (in ms): 57(1), 44.3(2), 54(3), 56.9(4), 52(5), 58(6). In this work, we evaluate 2 different sequences for T2 Maps, Turbo Spin Echo (TSE) and T2-prepared TrueFisp (T2P-SSFP), each with different protocols. Methods: Phantom study: We prepared 2 phantoms using different proportions of Agarose and NiCl2 to simulate T1 and T2 values in the range for normal myocardium (T1, T2) and edema (T1, T2). We evaluated the T2 values of these 2 phantoms using the traditional spin echo technique with a TR of 6 seconds and 9 images at the following TEs (in ms): 11, 25, 40, 60, 90, 120 160, 200, 250. After accounting for random noise in the received signal, the MR spin echo signal decays as follows: Signal = M0 exp(-t/T2) + N, where M0 is the initial magnetization and N is the random noise. We fit all three parameters to obtain accurate T2 values. We then tested 4 different protocols to generate T2 Maps, 2 each with T2P-SSFP and TSE sequences: TSE with 2 TE’s, TSE with 3 TE’s, T2P-SSFP with linear k-space re-ordering and 3 TE’s, T2P-SSFP with centric k-space re-ordering and 3 TE’s. We optimized these 4 protocols and used them to generate the T2 maps of phantoms using a 2 parameter model. The optimized protocol and imaging parameters are given in Table 1. In-vivo: 6 healthy volunteers were scanned in the study comprised of 2 parts: (1) To compare the performance of TSE and T2P-SSFP protocols, we generated T2 Maps of mid-ventricular SAX slice (2). Using the results of (1) and of phantom study which established the superiority of T2P-SSFP techniques, we acquired the T2 maps of the AHA recommended 16 segments (apex was not used) using T2P-SSFP (both linear and centric ordering) to compare for inter-subject variability (centric reordering) and more accurately compare centric vs linear ordering. ANOVA test was used to study the variability in T2 measurement with different techniques (n=36, 6 midventricular SAX segments for 6 subjects) and also to study the inter-subject T2 variability (n=16 segments for each subject); in addition, we compared linear and centric ordering using a paired t-test (n=96, 16 segments in 6 subjects); Tuckey’s correction was used for multiple comparison. p-value < 0.05 was considered significant. Results: Phantom: From Table 2, T2P-SSFP with centric ordering provided the most accurate T2 measurements, followed by T2P-SSFP with linear ordering. Both TSE methods significantly overestimated T2 values. In vivo: The differences in T2 values measured with the 4 protocols were statistically significant (p-value < 0.001). Pair-wise, only the 2 TSE techniques were similar (p-value=0.98, paired t-test) The T2 values in the 6 subjects from Centric ordered T2P-SSFP showed statistically significant variation (p-value < 0.001). Thus, instead of reporting a mean and SD, we report a range of observed values: 40.5 to 54.8 ms. The T2P-SSFP with linear ordering gave a T2 value higher than that given by centric ordering (paired ttest, p-value < 0.001). Although T2P-SSFP with centric ordering gave the highest accuracy in determining T2 values (based on the phantom study), the raw images with centric ordering had some artifact in blood pool which showed up in T2 Maps. This problem was not observed in linear ordering (Fig 1). Conclusion: We investigated 4 different protocols with 2 pulse sequences which can be used for T2 mapping of human myocardium. T2P-SSFP measured phantom T2’s more accurately than the TSE based techniques which overestimated T2; the possible reasons could be stimulated echoes and insufficient TR; increasing the TR is not feasible for subject breath-hold. Moreover, being single-shot, the imaging time is within acceptable breath-hold duration (7 RR intervals). Thus T2 mapping is an accurate and practical technique to detect T2 values across myocardium. Clinically, this technique can be used to detect subtle myocardial T2 changes due to edema associated with acute coronary syndrome. References: 1. Bottomley PA, et al. Med Phys. 1984; 11(4):425-48. 2. Mavrogeni SI, et al. MAGMA. 1998; 6(1):7-12. 3. Huang TY, et al. Magn Reson Med. 2007; 57(5):960-6. 4. He T, et al. J Magn Reson Imaging. 2006; 24(3):580-5. 5. Foltz WD, et al. Magn Reson Med. 2003; 49(6):1089-97. 6. Papanikolaou N, et al. Acta Radiol. 2000; 41(4):348-51. Table 1: Imaging parameters Parameter T2P-SSFP TSE Effective Echo times (ms) 0, 24, 55 {4.4, 53}, {4.4, 44, 84} Matrix 96 x 160 80 x 128 Slice (mm) 8 8 Flip angle (degrees) 40 90/180 TR 3 RR 3 RR PAT (acceleration/ref lines) 2/24 2/27 Imaging time 7 RR intervals 21 RR intervals
منابع مشابه
Reproducibility of slice-interleaved myocardial T2 mapping sequences
Background Myocardial T2 mapping sequence allows quantitative assessment of myocardial edema and inflammation. Commonly, a series of T2 weighted images with steadystate free-precession (SSFP) are acquired after T2 magnetization preparation (T2Prep) with different echo times. Conventionally, a single slice per breath-hold is acquired to image one single slice. Because inflammation/edema is often...
متن کاملT1 and T2 Mapping have a higher diagnostic accuracy for the ischaemic area-at-risk in NSTEMI patients compared with dark blood imaging
Background T1 and T2 mapping has shown great promise for the identification of acute myocardial infarction. However, most of this work has been performed in patients with ST-elevation myocardial infarction (STEMI). We prospectively studied the diagnostic accuracy of two novel (T1, T2 mapping) and one established (T2 STIR) MRI methods for imaging the ischaemic area-at-risk (AAR) in patients with...
متن کاملHigh spatial and temporal myocardial CINE T2* mapping at 7.0 T: a feasibility study
Background Myocardial tissue characterization using T2* relaxation mapping techniques is an emerging application of clinical cardiovascular magnetic resonance imaging. The increase in microscopic susceptibility at higher magnetic field strengths renders myocardial T2* mapping at ultrahigh magnetic fields conceptually appealing. This work demonstrates the feasibility of myocardial T2* imaging at...
متن کاملRobust myocardial T2 and T2* mapping at 3T
PURPOSE Intramyocardial hemorrhage and area at risk are both prognostic markers in acute myocardial infarction (AMI). Myocardial T2 and T2 * mapping have been used to detect such tissue changes at 1.5T but these techniques are challenging at 3.0T due to additional susceptibility variation. We studied T2 and T2 * myocardial mapping techniques at 3.0T on a system employing B1 shimming and compare...
متن کاملMyocardial T2* mapping: influence of noise on accuracy and precision
BACKGROUND Pixel-wise, parametric T2* mapping is emerging as a means of automatic measurement of iron content in tissues. It enables quick, intuitive interpretation and provides the potential benefit of spatial context between tissues. However, pixel-wise mapping uses much lower SNR data to estimate T2* when compared to region-based mapping thereby decreasing both its accuracy and precision. In...
متن کاملMyocardial Tissue Characterization by Magnetic Resonance Imaging
Cardiac magnetic resonance (CMR) imaging is a well-established noninvasive imaging modality in clinical cardiology. Its unsurpassed accuracy in defining cardiac morphology and function and its ability to provide tissue characterization make it well suited for the study of patients with cardiac diseases. Late gadolinium enhancement was a major advancement in the development of tissue characteriz...
متن کامل