Dry soda lime markedly degrades sevoflurane during simulated inhalation induction.
نویسندگان
چکیده
We have investigated gas composition during simulated inhalation induction with sevoflurane to elucidate possible mechanisms of incidental prolonged induction times and airway irritation. Using a circle system, 8% sevoflurane in oxygen 6 litre min-1 was washed into an absorbing canister filled with fresh soda lime containing 2.9% KOH (Draegersorb, 'D') or no KOH (< 0.01%, Sofnolime, 'S'). The absorbent was dried by oxygen 20,000 litre before every second experiment. Maximum soda lime temperatures attained after 4-6 min were 107 degrees C using dry D and 62 degrees C (61 degrees C) with dry S. Temperature did not increase with fresh soda lime. With dry soda lime, sevoflurane was not detected at the T-piece for 3 min and reached 6-7% within 6-10 min. After 1 min, we detected methanol and compound A (CH2F-O-C(= CF2) (CF3)). Total amounts over 20 min were: methanol 1125 mg (D dry), 334 mg (S dry) and < 5 mg (fresh soda lime); compound A 148 mg (D dry), 13 mg (S dry) and 3-8 mg (fresh); and fluoride 8.5 mg (D dry), 3.3 mg (S dry) and 1 mg (fresh). Formaldehyde was detected only with dry lime (D > 2.5 mg, S > 0.6 mg). In summary, the use of moist soda lime is of crucial importance during inhalation induction. With dry soda lime, the patient may inhale potentially toxic degradation products in significant amounts. Sevoflurane degradation is aggravated by a high KOH content of the lime. The observed airway irritation may be caused by formic acid, which is generated in isomolar concentrations with methanol (Cannizzaro reaction). The amount of compound A found with dry KOH-containing lime is unlikely to be noxious.
منابع مشابه
Halothane adsorption complicating the use of soda-lime to humidify anaesthetic gases.
If the anaesthetic circle system is arranged to increase the humidity of fresh anaesthetic gases by placing the carbon dioxide absorbent canister between the fresh gas inlet and the patient, drying of the soda-lime can occur. Very dry soda-lime adsorbs significant quantities of halothane. Using fresh soda-lime, effluent halothane concentration reached 50% of the input concentration in 35s, but ...
متن کاملEffects of low-flow sevoflurane anesthesia on renal function in low birth weight infants
BACKGROUND Low-flow sevoflurane anesthesia has been shown to influence renal function in rats, but not in adult humans. Presently, no study has assessed the effects of sevoflurane on renal function in low birth weight infants. Our aim was to study the renal function in low birth weight infants undergoing surgery with low-flow sevoflurane anesthesia. METHODS Forty infants graded as American So...
متن کاملReduction in nitrogen dioxide concentration by soda lime preparations during simulated nitric oxide inhalation.
Nitrogen dioxide is formed during delivery of inhaled nitric oxide for the treatment of patients with pulmonary hypertension. Soda lime has been shown to absorb nitrogen dioxide. We tested three different commercially available soda lime preparations (Sodasorb, Drägersorb 800 and Sofnolime) for their efficacy in absorbing nitrogen dioxide and nitric oxide during simulated nitric oxide inhalatio...
متن کاملNew inhalation agents in paediatric anaesthesia.
A survey in August 1995 showed that, despite the introduction of topical analgesic creams, approximately 30% of anaesthetists responding used inhalation induction of anaesthesia more frequently than i.v. induction, especially in children less than 3–5 yr of age.9 In this age group, uptake of inhaled agents is particularly rapid. In children therefore, the induction characteristics of the ideal ...
متن کاملSoda lime temperatures during low-flow sevoflurane anaesthesia and differences in dead-space.
BACKGROUND Sevoflurane degrades during low-flow anaesthesia to compound A, and high carbon dioxide absorbent temperatures cause increased degradation. The purpose of this investigation was to determine if larger tidal volumes, without increasing alveolar ventilation, decrease the temperature in the carbon dioxide absorber during low- and minimal-flow sevoflurane anaesthesia. METHODS Prospecti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 82 2 شماره
صفحات -
تاریخ انتشار 1999