Comparison of divergence-free algorithms for 3D MRI with three-directional velocity encoding
نویسندگان
چکیده
Background The velocity-to-noise ratio in 4D MR Flow acquisitions can suffer, particularly for low velocity segments, because the velocity encoding settings are adjusted to the highest velocities in the volume. Blood is essentially incompressible so vascular velocity fields should be divergence free. Therefore, any remaining divergence in an acquired 3D or 4D MR flow dataset can be assumed to originate from image noise, which can be reduced by imposing divergence free conditions. Several methods have been proposed to reconstruct a divergence free velocity vector field, yet to our knowledge no comparison studies exist to explore their properties in flow MRI data. This study compares two methods in their effectiveness at improving flow visualizations, the finite difference method (FDM)[1] and the radial basis function (RBF)[2] based approach, which differ in their handling of noise and boundary conditions.
منابع مشابه
Advanced Quantitative Flow and Wall Shear Stress Analysis at 3T: 2D Vs 3D Time-Resolved MR Velocity Mapping
Introduction: Time-resolved (CINE) phase contrast (PC) MRI permits the assessment of blood flow within entire 3D vascular structures [1, 2]. The resulting high-dimensional datasets (3 spatial dimensions, 3 velocity directions, and time) require new visualization and quantification methods to derive reliable clinical parameters. In this context, an advanced flow quantification tool was developed...
متن کامل4D Flow and 2D PC MRI: impact of volumetric coverage and three-directional velocity encoding on quantification of aortic hemodynamics
Background The accurate assessment of arterial blood flow is crucial for the diagnosis and management of patients with cardiovascular disease. Our aim was to systematically compare three phase-contrast (PC) MRI sequences for the quantification of aortic hemodynamics, including: 1) 2D time-resolved (CINE) PC MRI with one-directional through-plane (2D-1dir) velocity encoding; 2) 2D CINE PC MRI wi...
متن کاملImproving 3D MR Velocity-Vector Field Mapping by Divergence-Free Image Reconstruction
Introduction Phase-contrast magnetic resonance imaging (PC-MRI) provides time-resolved 3D information of velocity fields of flowing blood in vessels. It has however been noted that system imperfections including eddy current related phase offsets, sample noise, displacement and partial volume effects can compromise the accuracy of velocity data derived from phase-contrast measurements [1]. If o...
متن کاملParticle Trace Visualization of Cardiac Flow Patterns using 3D Phase Contrast MRI: An in vitro Comparison with Streamlines Created using Dye
Introduction Intracardiac flow patterns can be visualized by particle traces obtained from three-dimensional phase contrast MRI. Good results have been shown for stationary [1] and time-resolved data [2]. New off-line retrospective gated 3D phase contrast techniques, providing high resolution time-resolved 3D velocity data, have improved the accuracy of the calculated particle traces [3]. While...
متن کاملIncompressible smoothed particle hydrodynamics simulations on free surface flows
The water wave generation by wave paddle and a freely falling rigid body are examined by using an Incompressible Smoothed Particle Hydrodynamics (ISPH). In the current ISPH method, the pressure was evaluated by solving pressure Poisson equation using a semi-implicit algorithm based on the projection scheme and the source term of pressure Poisson equation contains both of divergence free ve...
متن کامل